arXiv · 0709.4514
An Improved Shashlyk Calorimeter
Abstract
Shashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction, selection of wave shifting fibers and photo-detectors, and development of a new scintillator with improved optical and mechanical properties are described. How the modules will perform in a large calorimeter was determined from prototype measurements. The experimentally determined characteristics of the calorimeter prototype show energy resolution of sigma_E/E=(1.96+-0.1)% \oplus (2.74+-0.05)%/sqrt{E}, time resolution of sigma_T = (72+-4)/sqrt{E} \oplus (14+-2)/E (ps), where photon energy E is given in GeV units and \oplus means a quadratic summation. A punch-through inefficiency of photon detection was measured to be ε= 5*10^{-5} (Θ>5 mrad).
Explore related subjects
Keep this discovery
G. S. Atoian, G. I. Britvich, S. K. Chernichenko, S. Dhawan, V. V. Issakov, O. V. Karavichev, T. L. Karavicheva, V. N. Marin, A. A. Poblaguev, I. V. Shein, A. P. Soldatov, M. E. Zeller. 2007-09-28. An Improved Shashlyk Calorimeter. https://doi.org/10.1016/j.nima.2007.10.022
Cite the original work for its findings. Save a collection to share your selection of sources.