Search arXivSearch

arXiv · 0807.2176

The SMC SNR 1E0102.2-7219 as a Calibration Standard for X-ray Astronomy in the 0.3-2.5 keV Bandpass

Abstract

The flight calibration of the spectral response of CCD instruments below 1.5 keV is difficult in general because of the lack of strong lines in the on-board calibration sources typically available. We have been using 1E 0102.2-7219, the brightest supernova remnant in the Small Magellanic Cloud, to evaluate the response models of the ACIS CCDs on the Chandra X-ray Observatory (CXO), the EPIC CCDs on the XMM-Newton Observatory, the XIS CCDs on the Suzaku Observatory, and the XRT CCD on the Swift Observatory. E0102 has strong lines of O, Ne, and Mg below 1.5 keV and little or no Fe emission to complicate the spectrum. The spectrum of E0102 has been well characterized using high-resolution grating instruments, namely the XMM-Newton RGS and the CXO HETG, through which a consistent spectral model has been developed that can then be used to fit the lower-resolution CCD spectra. We have also used the measured intensities of the lines to investigate the consistency of the effective area models for the various instruments around the bright O (~570 eV and 654 eV) and Ne (~910 eV and 1022 eV) lines. We find that the measured fluxes of the O VII triplet, the O VIII Ly-alpha line, the Ne IX triplet, and the Ne X Ly-alpha line generally agree to within +/-10 % for all instruments, with 28 of our 32 fitted normalizations within +/-10% of the RGS-determined value. The maximum discrepancies, computed as the percentage difference between the lowest and highest normalization for any instrument pair, are 23% for the O VII triplet, 24% for the O VIII Ly-alpha line, 13% for the Ne IX triplet, and 19% for the Ne X Ly-alpha line. If only the CXO and XMM are compared, the maximum discrepancies are 22% for the O VII triplet, 16% for the O VIII Ly-alpha line, 4% for the Ne IX triplet, and 12% for the Ne X Ly-alpha line.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul P. Plucinsky, Frank Haberl, Daniel Dewey, Andrew P. Beardmore, Joseph M. DePasquale, Olivier Godet, Victoria Grinberg, Eric D. Miller, A. M. T. Pollock, Steve Sembay, Randall K. Smith. 2008-07-14. The SMC SNR 1E0102.2-7219 as a Calibration Standard for X-ray Astronomy in the 0.3-2.5 keV Bandpass. https://doi.org/10.1117/12.789191

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Cosmic Conundrums with Quantum Corrections

Darh energy was discovered over 25 years ago and we do not have an explanation of it. Dark matter comprises 95% of matter in the universe and we still don't know what it is. The Webb telescope has been finding fully formed galaxies with massive black holes millions of times the mass of the sun in the early universe and we don't have any explanation. A quantum density limitation will be used to solve these and other outstanding problems.

astro-ph

On binary pulsars and the force of gravity

The energy-momentum budget of the astrophysical systems can be studied by the exact local conservation equation derived by Landau and Lifshitz. We show that a similar equation is valid for the Einstein-Cartan gravity. We reanalyze a binary pulsar system using the Landau-Lifshitz conservation equation and show that the orbital period change rate can be completely understood as a curvature backreaction process. Taking into account the detailed theoretical and observational research of relativistic binary pulsar systems, especially the system of Hulse and Taylor, we conclude that general relativity and astrophysical observations rule out the existence of gravitational radiation. We comment upon the LIGO GW events and their alternative explanation, as well as the recent pulsar timing arrays data.

astro-ph

Oscillation frequencies and mode lifetimes in alpha Centauri A

We analyse our recently-published velocity measurements of alpha Cen A (Butler et al. 2004). After adjusting the weights on a night-by-night basis in order to optimize the window function to minimize sidelobes, we extract 42 oscillation frequencies with l=0 to 3 and measure the large and small frequency separations. We give fitted relations to these frequencies that can be compared with theoretical models and conclude that the observed scatter about these fits is due to the finite lifetimes of the oscillation modes. We estimate the mode lifetimes to be 1-2 d, substantially shorter than in the Sun.

astro-ph