Microwave Technologies-- Determination of Magnetic and Dielectric Materials Microwave Properties

Abstract

In this study, four different techniques are presented. 1 Rectangular waveguide measurement technique for normal microwave materials microwave properties such as permeability and permittivity. This technique removed guess parameter and dispersive effect issues of the old waveguide measurement techniques. It projects a new route for determination of any microwave materials magnetic and dielectric properties without using any guesses. 2 Coaxial probe measurement technique for the liquid and biological tissues dielectric permittivity. This coaxial probe technique has an advantage which is to attain the highest reflected signal from the coaxial probe tip, so that it is a fast and very sensitive technique to differentiate lossy materials dielectric permittivity. This technique could be useful non destructive detections for tumors in hospital and non destructive detections for chemical liquids as well. 3 A microstripline measurement technique for oxides microwave measurement at low frequency spectra where the waveguide technique becomes robot and cumbersome. 4 A new methodology is presented for the rectangular waveguide technique to determine microwave metamaterials refractive index, permeability and permittivity using the rectangular waveguide. In summary, the presented techniques are capable enough to determine magnetic and non magnetic solid state materials, liquids, powders and biological tissues microwave properties from the broad microwave frequencies spectra between 1 GHz to 50 GHz. Lastly, a special ferrites microwave properties are also presented since the negative refractive index from the insulator ferrite could be an interesting subject.

Explore related subjects

Keep this discovery

BibTeXRIS

Mahmut Obol. 2009-06-16. Microwave Technologies-- Determination of Magnetic and Dielectric Materials Microwave Properties. https://arxiv.org/abs/0906.2928

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det