Search arXivSearch

arXiv · 1004.3325

Wavelength Calibration of the VLT-UVES Spectrograph

Abstract

We attempt to measure possible miscalibration of the wavelength scale of the VLT-UVES spectrograph. We take spectra of QSO HE0515-4414 through the UVES iodine cell which contains thousands of well-calibrated iodine lines and compare these lines to the wavelength scale from the standard thorium-argon pipeline calibration. Analyzing three exposures of this z = 1.71 QSO, we find two distinct types of calibration shifts needed to correct the Th/Ar wavelength scale. First, there is an overall average velocity shift of between 100 m/s and 500 m/s depending upon the exposure. Second, within a given exposure, we find intra-order velocity distortions of 100 m/s up to more than 200 m/s. These calibration errors are similar to, but smaller than, those found earlier in the Keck HIRES spectrometer. We discuss the possible origins of these two types of miscalibration. We also explore the implications of these calibration errors on the systematic error in measurements of the relative change in alpha (current value - past value) / current value, the change in the fine-structure constant derived from accurate measurement of the relative redshifts of absorption lines in QSO absorption systems. The overall average, exposure-dependent shifts should be less relevant for fine-structure work, but the intra-order shifts have the potential to affect these results. Using either our measured calibration offsets or a Gaussian model with sigma of around 90 m/s, Monte Carlo mock experiments find errors in the relative change in alpha of between 1e-6 Nsys^(-1/2) and 3e-6 Nsys^(-1/2), where Nsys is the number of systems used and the range is due to dependence on how many metallic absorption lines in each system are compared.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jonathan B. Whitmore, Michael T. Murphy, Kim Griest. 2010-09-21. Wavelength Calibration of the VLT-UVES Spectrograph. https://doi.org/10.1088/0004-637x%2F723%2F1%2F89

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM