Abstract
The FLASH L-band (1.3 GHz) superconducting accelerator facility at DESY has a Low Level RF (LLRF) system that is similar to that envisioned for ILC. This system has extensive monitoring capability and was used to gather performance data relevant to ILC. Recently, waveform data were recorded with both beam on and off for three, 8-cavity cryomodules to evaluate the input RF and cavity gradient stability and study the rf overhead required to achieve constant gradient during the 800\mu\s pulses. In this paper, we present the recent experimental results and discuss the pulse-to-pulse input rf and cavity gradient stability for both the beam on and off cases. In addition, a model of the gradient variation observed in the beam off case will be described.
Explore related subjects
Keep this discovery
Shilun Pei, Chris E. Adolphsen, John Carwardine, Nicholas John Walker. 2010-05-27. Latest Results on Cavity Gradient and Input RF Stability at FLASH/TTF Facility. https://arxiv.org/abs/1005.5149
Cite the original work for its findings. Save a collection to share your selection of sources.