arXiv · 1011.5528
First results of spherical GEMs
Abstract
We developed a method to make GEM foils with a spherical geometry. Tests of this procedure and with the resulting spherical GEMs are presented. Together with a spherical drift electrode, a spherical conversion gap can be formed. This eliminates the parallax error for detection of x-rays, neutrons or UV photons when a gaseous converter is used. This parallax error limits the spatial resolution at wide scattering angles. Besides spherical GEMs, we have developed curved spacers to maintain accurate spacing, and a conical field cage to prevent edge distortion of the radial drift field up to the limit of the angular acceptance of the detector. With these components first tests are done in a setup with a spherical entrance window but a planar readout structure; results will be presented and discussed. A flat readout structure poses difficulties, however. Therefore we will show advanced plans to make a prototype of an entirely spherical double-GEM detector, including a spherical 2D readout structure. This detector will have a superior position resolution, also at wide angles, and a high rate capability.
Explore related subjects
Keep this discovery
Serge Duarte Pinto, Matteo Alfonsi, Ian Brock, Gabriele Croci, Eric David, Rui de Oliveira, Leszek Ropelewski, Miranda van Stenis, Hans Taureg, Marco Villa. 2010-11-24. First results of spherical GEMs. https://doi.org/10.1109/nssmic.2010.5874100
Cite the original work for its findings. Save a collection to share your selection of sources.