arXiv · 1209.1338
Plate Fin Heat Exchanger Model with Axial Conduction and Variable Properties
Abstract
Future superconducting radio frequency (SRF) cavities, as part of Project X at Fermilab, will be cooled to superfluid helium temperatures by a cryogenic distribution system supplying cold supercritical helium. To reduce vapor fraction during the final Joule-Thomson (J-T) expansion into the superfluid helium cooling bath, counter-flow, plate-fin heat exchangers will be utilized. Due to their compact size and ease of fabrication, plate-fin heat exchangers are an effective option. However, the design of compact and high-effectiveness cryogenic heat exchangers operating at liquid helium temperatures requires consideration of axial heat conduction along the direction of flow, in addition to variable fluid properties. Here we present a numerical model that includes the effects of axial conduction and variable properties for a plate fin heat exchanger. The model is used to guide design decisions on heat exchanger material choice and geometry. In addition, the J-T expansion process is modeled with the heat exchanger to analyze the effect of heat load and cryogenic supply parameters.
Explore related subjects
Keep this discovery
B. J. Hansen, M. J. White, A. Klebaner. 2012-09-06. Plate Fin Heat Exchanger Model with Axial Conduction and Variable Properties. https://doi.org/10.1063/1.4706971
Cite the original work for its findings. Save a collection to share your selection of sources.