Search arXivSearch

arXiv · 1209.5431

Automatic Electric Meter Reading System: A Cost-Feasible Alternative Approach In Meter Reading For Bangladesh Perspective Using Low-Cost Digital Wattmeter And Wimax Technology

Abstract

Energy meter reading is a monotonous and an expensive task. Now the meter reader people goes to each meter and take the meter reading manually to issue the bill which will later be entered in the billing software for billing and payment automation. If the manual meter reading and bill data entry process can be automated then it would reduced the laborious task and financial wastage. "Automatic Electric Meter Reading (AMR) System" is a metering system that is to be used for data collecting from the meter and processing the collected data for billing and other decision purposes. In this paper we have proposed an automatic meter reading system which is low cost, high performance, highest data rate, highest coverage area and most appropriate for Bangladesh perspective. In this AMR system there are four basic units. They are reading unit, communication unit, data receiving and processing unit and billing system. For reading unit we identified the disk rotation of the energy meter and stored the data in microcontroller. So it is not required to change the current analog energy meter. An external module will be added with the current energy meter. In the communication unit Wimax transceiver was used for wireless communication between meter end and the server end because of its wide coverage area. In the data receiving and processing unit meter reading will be collected from the transceiver which is controlled by another microcontroller. There will be a computer application that will take the data from the microcontroller. This will also help to avoid any tampering or break down of energy meter. There are various AMR system exists all over the world. Those systems were analyzed and we found they are not feasible for Bangladesh.

Explore related subjects

Keep this discovery

BibTeXRIS

Tanvir Ahmed, Md. Suzan Miah, Md. Manirul Islam, Md. Rakib Uddin. 2012-09-24. Automatic Electric Meter Reading System: A Cost-Feasible Alternative Approach In Meter Reading For Bangladesh Perspective Using Low-Cost Digital Wattmeter And Wimax Technology. https://arxiv.org/abs/1209.5431

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Circular Economy Synergies and Trade-offs in Data Centres

This report analyses data centre (DC) sustainability and circularity, revealing existing synergies and trade-offs: The PUE is too coarse, mixing cooling and power provisioning. It wrongly attributes server fan consumption and transformation losses to IT energy. It does not measure compute but infrastructure efficiency, which is already outstanding. Compute energy, however, is exploding. Better energy metrics for DCs would thus cover i) compute efficiency, ii) transformation efficiency, and iii) cooling overhead. Trade-offs exist between cooling energy and water as well as on-site and upstream water: Consuming water on-site lowers the cooling energy, which also lowers the water consumed upstream in power generation. For 'wet' electricity, there is little competition: It is worth spending more on-site energy to save both electricity and related upstream water. For 'dry' electricity, there is a trade-off. Waste heat recovery brings energy circularity but has limited uses and is not the same energy quality, a fact not reflected by current metrics. A better metric would consider the avoided energy through heat recovery instead of the amount recovered. Material circularity can be achieved by interpreting the 9R framework in the context of DCs. Circularity-enhancing measures can be categorised into product design, process design and business models, choice of materials, and operating conditions. Together, they have effects across all circularity levels. The relation between DCs and the power grid is complex. Modern DCs present new challenges for the grid. Mitigation includes battery storage and onsite generation. These measures have, in turn, further consequences, both beneficial and detrimental. They can offer grid flexibility as well as innovations in the field of energy. But they also bring noise, pollution, and GHGs, and compete with the energy sector for resources.

cs.OH

Digital Twin Modeling of a Highly Automated Agricultural Tractor

In efforts to increase research efficiency and availability, a digital twin of our research tractor (AMX G-trac) is created, focusing especially on the CAN communication for data reading and actuation command following the ISOBUS protocol. Mevea Simulation Software is utilized as the foundation, providing the kinematic model and visuals, while Python is used to read and write CAN messages over a Kvaser CanKing virtual CAN channel. Various performance tests involving straight line and turning behavior are performed in both the digital twin simulation and in the real world to measure similarity. Results indicate that the Mevea model behaves very comparable in its lateral dynamics, often within 5-10 percent, but requires better data to fully capture the longitudinal aspects like acceleration. The final model described in this paper sets the table for a second iteration to include more tractor functions such as hydraulics and tractor-implement dynamics.

cs.OH

Risk-based Design for Sustainability in Cloud Systems: Insights from an Experts' Survey

Cloud Systems' Sustainability is critical in Cloud Computing, especially with the growing demand in many industries. Sustainability risks in Cloud Computing can be tricky, mostly because of system complexity and their impact on performance. Thus, this research focuses on Risk-based design (RBD) and how it can support the early identification of possible risks for Cloud System Sustainability, as well as respective mitigation strategies of each risk. In order to successfully identify risks of Cloud System Sustainability, an Expert Survey is conducted including experts with different roles from different industries, to identify possible sustainability risks of a Cloud System on all different levels. Thematic analysis of the responses resulted in a categorization of risks, as well as in the identification of mitigation strategies and factors affecting each risk. Such findings can be helpful for researchers and practitioners that utilize RBD when building sustainable Cloud systems.

cs.OH