Search arXivSearch

arXiv · 1302.2583

Functionalized AFM probes for force spectroscopy: eigenmodes shape and stiffness calibration through thermal noise measurements

Abstract

The functionalization of an Atomic Force Microscope (AFM) cantilever with a colloidal bead is a widely used technique when the geometry between the probe and the sample must be controlled, particularly in force spectroscopy. But some questions remain: how does a bead glued at the end of a cantilever influence its mechanical response ? And more important for quantitative measurements, can we still determine the stiffness of the AFM probe with traditional techniques? In this article, the influence of a colloidal mass loading on the eigenmodes shape and resonant frequency is investigated by measuring the thermal noise on rectangular AFM microcantilevers with and without a bead attached at their extremities. The experiments are performed with a home-made ultra-sensitive AFM, based on differential interferometry. The focused beam from the interferometer probes the cantilever at different positions and the spatial shapes of the modes are determined up to the fifth resonance, without external excitation. The results clearly demonstrate that the first eigenmode almost doesn't change by mass loading. However the oscillation behavior of higher resonances present a marked difference: with a particle glued at its extremity, the nodes of the mode are displaced towards the free end of the cantilever. These results are compared to an analytical model taking into account the mass and the inertial moment of the load in an Euler-Bernoulli framework, where the normalization of the eigenmodes is explicitly worked out in order to allow a quantitative prediction of the thermal noise amplitude of each mode. A good agreement between the experimental results and the analytical model is demonstrated, allowing a clean calibration of the probe stiffness.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Justine Laurent, Audrey Steinberger, Ludovic Bellon. 2013-05-08. Functionalized AFM probes for force spectroscopy: eigenmodes shape and stiffness calibration through thermal noise measurements. https://doi.org/10.1088/0957-4484%2F24%2F22%2F225504

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Inverse Purcell Suppression of Decoherence in Majorana Qubits via Environmental Engineering

We show that the electromagnetic or phononic environment of a topological quantum device can be engineered to actively suppress decoherence. For a Majorana qubit in a superconducting wire, the exponentially small splitting $ε\sim e^{-L/ξ}$ that provides topological protection also makes the qubit vulnerable to low-frequency noise. From a microscopic local interaction, we derive the effective low-energy coupling between the Majorana parity operator and a bosonic field; the coupling strength itself is proportional to $ε$, reflecting the qubit's non-local nature. The resulting pure-dephasing rate scales as $Γ_ϕ\propto ε^2 S(ε)$, with $S(ε)$ the environmental noise power at frequency $ε$. In the experimentally relevant high-temperature regime ($k_B T \gtrsim \hbarε$), this gives $Γ_ϕ\propto ερ(ε) T$, where $ρ(ε)$ is the environmental density of states. By engineering an environment with a suppressed low-frequency density of states, $ρ_{\text{eng}}(ω) = ρ_0 (ω/ω_c)^α$ for $ω< ω_c$ ($α> 0$), the dephasing rate drops to $Γ_ϕ^{\text{eng}} \propto ε^{α+1} \propto e^{-(α+1)L/ξ}$. Thus, longer wires yield exponentially better coherence---a direct synergy with topological protection. This "inverse Purcell" effect, which suppresses the density of states at the qubit frequency, provides a quantitative design principle for environmental engineering. Our work establishes spectral density shaping as a practical method for enhancing coherence in topological quantum devices.

cond-mat.mes-hall

Axionic tunneling from a topological Kondo insulator

Discoveries over the past two decades have revealed the remarkable ability of quantum materials to emulate relativistic properties of the vacuum, from Dirac cones in graphene to Dirac surface states of topological insulators. Yet one of the most elusive consequences of topology in quantum matter -- the axionic ${\bf E}\cdot{\bf B}$ contribution to the electromagnetic response, predicted to produce strong magnetoelectric effects -- remains experimentally challenging to detect. Here we report evidence for an axion-like magnetoelectric response obtained through scanning tunneling microscopy (STM) using a SmB$_6$ nanowire tip on an antiferromagnetic Fe$_{1+x}$Te sample. Our measurements reveal a striking voltage-induced magnetization: millivolt biases generate measurable tip magnetizations that reverse with the voltage. The magnitude, tunability, and reversibility of this signal are consistent with an axion-like ${\bf E} \cdot {\bf B}$ coupling, which naturally accounts for the voltage-odd magnetic component of the tip spectral function while strongly constraining a conventional static-magnetism interpretation. Moreover, millivolt-scale control of spin polarization in a tunnel junction provides a new route for probing axionic electrodynamics and opens avenues for future STM and spintronic applications.

cond-mat.mes-hall

Exciton-mediated optical control of liquid-solid friction

Interfacial friction in nanofluidic systems can arise from fluctuation-induced coupling between liquid charge fluctuations and the internal excitations of the confining solid. Here, we develop a microscopic theory of exciton-mediated solid-liquid friction based on the coupling between optically generated excitons and charge fluctuations in water. We distinguish between static excitons, localized by disorder or functionalization, and dynamic excitons, which interact with water through polarization fluctuations. In both cases, we derive analytical formulas for the excitonic friction, which is experimentally tunable and can significantly reduce the slip length and thereby the hydraulic permeability of nanochannels. Applying our framework to carbon nanotubes, we quantitatively reproduce the recent measurements of Kistwal et al., showing a reduction of nanotube diffusion under optical excitation, without fitting parameters. More broadly, our results establish excitons as a mechanism to optically control nanofluidic transport and suggest that excitonic photoluminescence could provide an optical probe of flow velocity inside nanochannels.

cond-mat.mes-hall