Learning about SANS Instruments and Data Reduction from Round Robin Measurements on Samples of Polystyrene Latex

Abstract

Measurements of a well-characterised standard sample can verify the performance of an instrument. Typically, small-angle neutron scattering instruments are used to investigate a wide range of samples and may often be used in a number of configurations. Appropriate standard samples are useful to test different aspects of the performance of hardware as well as that of the data reduction and analysis software. Measurements on a number of instruments with different intrinsic characteristics and designs in a round robin can not only better characterise the performance for a wider range of conditions but also, perhaps more importantly, reveal the limits of the current state of the art of small-angle scattering. The exercise, followed by detailed analysis, tests the limits of current understanding as well as uncovers often forgotten assumptions, simplifications and approximations that underpin the current practice of the technique. This paper describes measurements of polystyrene latex, radius 72 nm with a number of instruments. Scattering from monodisperse, uniform spherical particles is simple to calculate and displays sharp minima. Such data test the calibrations of intensity, wavelength and resolution as well as the detector response. Smoothing due to resolution, multiple scattering and polydispersity has been determined. Sources of uncertainty are often related to systematic deviations and calibrations rather than random counting errors. The study has prompted development of software to treat modest multiple scattering and to better model the instrument resolution. These measurements also allow checks of data reduction algorithms and have identified how they can be improved. The reproducibility and the reliability of instruments and the accuracy of parameters derived from the data are described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adrian R. Rennie, Maja S. Hellsing, Kathleen Wood, Elliot P. Gilbert, Lionel Porcar, Ralf Schweins, Charles D. Dewhurst, Peter Lindner, Richard K. Heenan, Sarah E. Rogers, Paul D. Butler, Jeffery R. Krzywon, Ron E. Ghosh, Andrew J. Jackson, Marc Malfois. 2013-07-31. Learning about SANS Instruments and Data Reduction from Round Robin Measurements on Samples of Polystyrene Latex. https://doi.org/10.1107/s0021889813019468

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Deformation and organization of droplet-encapsulated soft beads

Many biological, culinary, and engineering processes lead to the co-encapsulation of several soft particles within a liquid interface. In these situations the particles are bound together by the capillary forces that deform them and influence their biological or rheological properties. Here, we introduce an experimental approach to encapsulate a controlled number of soft beads within aqueous droplets in oil. These droplet-encapsulated gels are manipulated in a deformable microfluidic device to merge them and modify the liquid fraction. In the dry limit the contact surface between the hydrogels is found to be determined by the elastocapillary number $E_c$, with the contact radius following a $E_c^{1/3}$ dependence, indicating that the deformation increases for soft or small particles. When multiple beads are co-encapsulated within a single droplet they can be arranged into linear or three-dimensional aggregates that remain at a local energy minimum.

cond-mat.soft

Flexoelectricity-driven softening of bend elasticity leads to spontaneous chiral symmetry breaking in a polar fluid

The origin of the recently observed spontaneous chiral symmetry breaking in polar fluids composed of achiral molecules is an unsolved problem, raising fundamental questions about how heliconical structures emerge in such systems. Here, we investigate the pretransitional fluctuations leading to the formation of the spontaneously chiral twist-bend ferroelectric nematic phase using dielectric spectroscopy, light scattering, and small-angle X-ray scattering. We observe simultaneous softening of the bend elastic constant and the emergence of a collective dielectric mode on approaching the transition. By developing a theoretical model, we show that these phenomena are signatures of a flexoelectricity-driven transition arising from the coupling between electric polarization and bend deformation.

cond-mat.soft

Taylor dispersion in a soft tube

Diffusion of a solute along a tube is enhanced by hydrodynamic flow, a phenomenon known as Taylor dispersion. In microfluidic applications, the compliance of the tube boundaries modifies the hydrodynamic flow and thus solutal transport. Here, we develop the theory of solutal dispersion in a soft, axisymmetric tube where the tube walls respond to the hydrodynamic pressure through a Winkler response. By deriving the modified macro-transport equation for the solutal concentration dynamics based on multiple-time-scale analysis, we explore the influence of softness on solutal transport for steady and pulsatile configurations. Our main finding is that softness enhances the effective advection velocity and dispersion coefficient, which might have practical implication in biology and microfluidic technology.

cond-mat.soft