Search arXivSearch

arXiv · 1406.5179

Elimination of a Second-Law-attack, and all cable-resistance-based attacks, in the Kirchhoff-law-Johnson-noise (KLJN) secure key exchange system

Abstract

We introduce the so far most efficient attack against the Kirchhoff-law-Johnson-noise (KLJN) secure key exchange system. This attack utilizes the lack of exact thermal equilibrium in practical applications and is based on cable resistance losses and the fact that the Second Law of Thermodynamics cannot provide full security when such losses are present. The new attack does not challenge the unconditional security of the KLJN scheme, but it puts more stringent demands on the security/privacy enhancing protocol than for any earlier attack. In this paper we present a simple defense protocol to fully eliminate this new attack by increasing the noise-temperature at the side of the smaller resistance value over the noise-temperature at the at the side with the greater resistance. It is shown that this simple protocol totally removes Eve's information not only for the new attack but also for the old Bergou-Scheuer-Yariv attack. The presently most efficient attacks against the KLJN scheme are thereby completely nullified.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laszlo B. Kish, Claes-Goran Granqvist. 2014-09-28. Elimination of a Second-Law-attack, and all cable-resistance-based attacks, in the Kirchhoff-law-Johnson-noise (KLJN) secure key exchange system. https://doi.org/10.3390/e16105223

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Beyond HBM-on-GPU: Thermal Design Envelope for 3D Volumetric DRAM-on-GPU Integration

The scaling of GPUs for AI and HPC workloads is increasingly constrained by the capacity, bandwidth, and thermal limits of both 2.5D HBM-GPU and direct-stacked 3D HBM-on-GPU integration. This work establishes the thermal design envelope for 3D volumetric DRAM-on-GPU integration, in which vertically oriented DRAM dies and interleaved cooling cavities reshape heat flow and memory interfacing above the GPU. Using a package-level thermal model anchored to a consistent HBM-on-GPU baseline and driven by a realistic reticle-scale non-uniform GPU power map, we quantify the key parameters governing thermal feasibility. Stack height is the dominant limiter of peak temperature, while cooling-cavity conductivity shifts the feasible region, and mold insertion and stack orientation further modulate thermal behavior. A distributed memory-controller and network-on-chip tier introduces only a moderate thermal penalty. Although die-level parallelism increases bandwidth, the reduction in simulated training time saturates once execution becomes compute-bound. These results define a bounded co-design space across bandwidth, capacity, and thermal constraints for 3D volumetric DRAM-on-GPU integration.

cs.ET

Droop-Aware Foundation Model Power Flow

This paper develops a droop-aware extension of the GridFM power systems foundation model, embedding droop gains and frequency/voltage deadband parameters as per-bus node features to enable control-aware AC power-flow analysis. Existing power-flow datasets encode only static electrical features, conflating operating points from qualitatively different control regimes; this work resolves that gap by exposing droop and deadband parameters as structured node features, with deadband discontinuities handled through a smooth tanh approximation that preserves solver differentiability. A transformer-based graph neural network is pre-trained on masked reconstruction and fine-tuned on the resulting control-aware datasets. The framework is validated against PSCAD electromagnetic-transient simulations on a two-bus system (0.11% maximum steady-state error) and cross-validated against an independent PyPower droop solver on the IEEE 24-bus RTS. On the 24-bus system the surrogate attains R2 = 0.9996 for active generation and 0.0015 p.u. voltage-magnitude RMSE; scalability is confirmed on the IEEE 300-bus system (0.0036 p.u. RMSE, R2 = 0.9841 for voltage magnitude across 299,700 predictions). A three-mode control study further shows that the deadband widens the control-error distribution while leaving total droop compensation unchanged, establishing deadband width as an actionable node-level design feature.

cs.ET

GNN-based Path-aware multi-view Circuit Learning for Technology Mapping

Traditional technology mapping suffers from systemic inaccuracies in delay estimation due to its reliance on abstract, technology-agnostic delay models that fail to capture the nuanced timing behavior behavior of real post-mapping circuits. To address this fundamental limitation, we introduce GPA(graph neural network (GNN)-based Path-Aware multi-view circuit learning), a novel GNN framework that learns precise, data-driven delay predictions by synergistically fusing three complementary views of circuit structure: And-Inverter Graphs (AIGs)-based functional encoding, post-mapping technology emphasizes critical timing paths. Trained exclusively on real cell delays extracted from critical paths of industrial-grade post-mapping netlists, GPA learns to classify cut delays with unprecedented accuracy, directly informing smarter mapping decisions. Evaluated on the 19 EPFL combinational benchmarks, GPA achieves 19.9%, 2.1% and 4.1% average delay reduction over the conventional heuristics methods (techmap, MCH) and the prior state-of-the-art ML-based approach SLAP, respectively-without compromising area efficiency.

cs.ET