Search arXivSearch

arXiv · 1409.1298

Aging research of the LAB-based liquid scintillator in stainless steel container

Abstract

Stainless steel is the material used for the storage vessels and piping systems of LAB-based liquid scintillator in JUNO experiment. Aging is recognized as one of the main degradation mechanisms affecting the properties of liquid scintillator. LAB-based liquid scintillator aging experiments were carried out in different material of containers (type 316 and 304 stainless steel and glass) at two different temperature (40 and 25 degrees Celsius). For the continuous liquid scintillator properties tests, the light yield and the absorption spectrum are nearly the same as that of the unaged one. The attenuation length of the aged samples is 6%~12% shorter than that of the unaged one. But the concentration of element Fe in the LAB-based liquid scintillator does not show a clear change. So the self aging has small effect on liquid scintillator, as well as the stainless steel impurity quenching. Type 316 and 304 stainless steel can be used as LAB-based liquid scintillator vessel, transportation pipeline material.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hai-tao Chen, Bo-xiang Yu, Qing Shan, Ya-yun Ding, Bing Du, Shu-tong Liu, Xuan Zhang, Li Zhou, Wen-bao Jia, Jian Fang, Xing-chen Ye, Wei Hu, Shun-li Niu, Jia-qing Yan, Hang Zhao, Dao-jin Zhao. 2014-09-04. Aging research of the LAB-based liquid scintillator in stainless steel container. https://arxiv.org/abs/1409.1298

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det