Search arXivSearch

arXiv · 1410.1587

Enhancing spatial resolution of soft x-ray CCD detectors by single-photon centroid determination

Abstract

In Charge Coupled Device (CCD) detectors the electrons excited upon absorption of a single x-ray photon quickly diffuse and generate charge-spots often larger than pixel dimensions. In the soft x-ray range this phenomenon drastically limits the effective spatial resolution to approximately 25μm, irrespective of the pixel size. For very low fluence the charge-cloud centroid determination can be used, on each individual spot, to estimate the actual photon impact position with sub-pixel precision. The readout noise and speed, together with the charge and spatial undersampling, are the main factors limiting the accuracy of this procedure in commercial devices. We have developed and extensively tested an algorithm for efficient centroid reconstruction on images acquired by low noise detectors not designed for single photon counting. We have thus measured a position uncertainty of 6-7μm in CCDs with 13.5μm and 20.0μm pixel size, around 1 keV photon energy. We have analyzed the centroid calculation performances by modelling the spot generation process. We show how the resolution is affected by both random uncertainty, mainly ascribed to the readout noise, and systematic error, due to the undersampling of the charge spot. This study was motivated by the growing need of of high-resolution high-sensitivity 2D position sensitive detectors in resonant inelastic (soft) x-ray scattering (RIXS), an emergent synchrotron radiation based spectroscopy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrea Amorese, Greta Dellea, Lucio Braicovich, Giacomo Ghiringhelli. 2014-10-06. Enhancing spatial resolution of soft x-ray CCD detectors by single-photon centroid determination. https://arxiv.org/abs/1410.1587

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det