Search arXivSearch

arXiv · 1504.08335

UK low-background infrastructure for delivering SuperNEMO

Abstract

SuperNEMO is a next generation neutrinoless double beta decay experiment with a design capability to reach a half-life sensitivity of $10^{26}$ years corresponding to an effective Majorana neutrino mass of $\langle m_{\beta\beta} \rangle$ $<$ 50 - 100 meV. To achieve this sensitivity, stringent radio-purity requirements are imposed resulting in an equally stringent screening programme. Dedicated facilities have been established in the UK for screening and selection of detector construction materials. Gamma ray spectroscopy using high-purity germanium (HPGe) detectors has been the standard method for the measurement of material contamination. A low-background facility has been established at Boulby Underground Laboratory. The first results from the 2 current HPGe detector are shown. Radon is one of the most critical backgrounds for SuperNEMO and most other low background experiments. It can enter the detector either through diffusion, contamination during construction or emanation from the detector materials resulting in radioactive daughter isotopes. To reach the target sensitivity, the $^{222}$Rn concentration inside the SuperNEMO tracker volume must be less than 150 $\mu$Bq/m3. A "Radon Concentration Line" (RnCL) was developed to be used in conjunction with a state-of-the-art radon detector to make a more sensitive measurement of large gas volumes. This apparatus has now been commissioned and is capable of measuring radon levels in large samples down to 10 $\mu$Bq/m3. The results from first measurements of radon content using the RnCL are presented. These measurements include gas bottles, boil-off nitrogen and a SuperNEMO sub-module during the early stages of construction.

Explore related subjects

Keep this discovery

BibTeXRIS

Xin Ran Liu. 2015-04-30. UK low-background infrastructure for delivering SuperNEMO. https://arxiv.org/abs/1504.08335

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det