Search arXivSearch

arXiv · 1507.07959

Refraction of light by light in vacuum

Abstract

In very intense electromagnetic fields, the vacuum refractive index is expected to be modified due to nonlinear quantum electrodynamics (QED) properties. Several experimental tests using high intensity lasers have been proposed to observe electromagnetic nonlinearities in vacuum, such as the diffraction or the reflection of intense laser pulses. We propose a new approach which consists in observing the refraction, i.e. the rotation of the waveplanes of a probe laser pulse crossing a transverse vacuum index gradient. The latter is produced by the interaction of two very intense and ultra short laser pulses, used as pump pulses. At the maximum of the index gradient, the refraction angle of the probe pulse is estimated to be $0.2 \times (\frac{w_0}{10 \mathrm{μm}})^{-3} \times \frac{I}{1 \mathrm{J}}$~picoradians, where $I$ is the total energy of the two pump pulses and $w_0$ is the minimum waist (fwhm) at the interaction area. Assuming the most intense laser pulses attainable by the LASERIX facility ($I = 25$~J, 30~fs fwhm duration, 800~nm central wavelength) and assuming a minimum waist of $w=10 \mathrm{μm}$ (fwhm) (corresponding to an intensity of the order of $10^{21}$~W/cm$^2$), the expected maximum refraction angle is about 5~picoradians. An experimental setup, using a Sagnac interferometer, is proposed to perform this measurement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

X. Sarazin, F. Couchot, A. Djannati-Atai, O. Guilbaud, S. Kazamias, M. Pittman, M. Urban. 2015-12-02. Refraction of light by light in vacuum. https://doi.org/10.1140/epjd%2Fe2015-60428-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Rubidium referenced Kerr comb with cavity phase matching

Phase matching is a fundamental problem in nonlinear optics that is normally constrained by material dispersion. The limited operation wavelengths within phase matching window limits the application, including the precise metrology using Kerr combs. Demanding applications like compact optical clock and astronomical spectroscopy requires atomic reference around 800 nm, where the natural phase matching is challenging. Here we revisit the concept of cavity phase matching (CPM), and fully reveal its advantage to engineer artificial phase matching beyond material dispersion. With the access of CPM condition in a monolithic high-Q fiber Fabry-Pérot resonator featuring a macroscopic cavity length, we achieve low noise Kerr comb generation around 800 nm, within the power budget of a single-mode laser diode. Inside a pump-integrated package of 19 cm3, low phase noise of -125 dBc/Hz at 100 kHz offset frequency is achieved for a 10.1 GHz repetition rate. Most importantly, the generated Kerr comb has been directly referenced to rubidium atomic transition for long-term stable operation. This result not only opens a new way for Kerr comb generation at arbitrary wavelengths, but also can be generalized to any other nonlinear optical frequency conversion application.

physics.optics

Mid-infrared reconfiguration of population flow in lanthanide nanocrystals

Converting mid-infrared (MIR) radiation to visible or near-infrared wavelengths is essential for imaging and sensing, yet achieving sensitive, low-power, and scalable detection remains challenging. Lanthanide nanocrystals provide an alternative through ratiometric luminescence but are typically constrained by Boltzmann statistics, which tie population distributions to lattice temperature and limit signal contrast. Here we show that MIR irradiation rebalances dissipative relaxation pathways, driving lanthanide emitters into a non-Boltzmann steady state that enables non-thermal control of population distributions. This allows emission behaviors inaccessible under thermal equilibrium. We exploit this regime to achieve linear MIR detection with respect to MIR power across 6.8 to 8.6 micrometers. The ratiometric response is intrinsically independent of the pump power, enabling operation at an ultralow excitation power of 10 uW, several orders of magnitude lower than conventional approaches. Using standard silicon photodetectors, we then demonstrate room-temperature MIR imaging with detection limits approaching 4 nW um-2. Our results establish lanthanide nanoparticles as an efficient platform for MIR conversion and sensing in nanophotonic systems.

physics.optics

Intracavity THz generation using a thin lithium niobate plate in a compact Kerr-lens mode-locked Yb:CALGO bulk oscillator

We demonstrate intracavity terahertz (THz) generation via optical rectification in a 50-m-thick lithium niobate crystal placed inside a compact diode-pumped Kerr-lens mode-locked (KLM) Yb:CALGO bulk oscillator. The oscillator operates at a repetition rate of 85 MHz and delivers 83-fs pulses with up to 71 W of average intracavity power, obtained with only 21.4 W of low-cost multimode diode pump power. We generate single-cycle THz pulses with a spectrum extending up to 3 THz, detected by electro-optic sampling with 60 dB dynamic range within 156 s of measurement time (313 averaged traces) and up to 120 W of THz average power. This work combines the high damage threshold, power-handling capability, and cost-effectiveness of thin LN plates with simplicity, compactness, and low-cost multimode diode-pumped solid-state bulk lasers, offering an attractive alternative for high-repetition-rate THz time-domain spectroscopy systems.

physics.optics