Search arXivSearch

arXiv · 1601.04582

Frequency ratio of Yb and Sr clocks with $5 \times 10^{-17}$ uncertainty at 150 s averaging time

Abstract

Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of $10^{-18}$, where full frequency descriptions are far beyond the reach of the SI second. Frequency ratios of such super clocks, on the other hand, are not subject to this limitation. They can therefore verify consistency and overall accuracy for an ensemble of super clocks, an essential step towards a redefinition of the second. However, with the measurement stabilities so far reported for such frequency ratios, a confirmation to $1 \times 10^{-18}$ uncertainty would require an averaging time $τ$ of multiple months. Here we report a measurement of the frequency ratio of neutral ytterbium and strontium clocks with a much improved stability of $4 \times 10^{-16} (τ/s)^{-1/2}$. Enabled by the high stability of optical lattice clocks interrogating hundreds of atoms, this marks a 90-fold reduction in the required averaging time over a previous record-setting experiment that determined the ratio of Al+ and Hg+ single-ion clocks to an uncertainty of $5.2 \times 10^{-17}$. For the Yb/Sr ratio, we find R = 1.207 507 039 343 337 749(55), with a fractional uncertainty of $4.6 \times 10^{-17}$.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Nils Nemitz, Takuya Ohkubo, Masao Takamoto, Ichiro Ushijima, Manoj Das, Noriaki Ohmae, Hidetoshi Katori. 2016-01-18. Frequency ratio of Yb and Sr clocks with $5 \times 10^{-17}$ uncertainty at 150 s averaging time. https://doi.org/10.1038/nphoton.2016.20

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Effective Conservation and Bistability of Atomic Alignment under Strong Spin~Exchange

We present a phenomenological model of anomalous alignment signals in dense cesium vapor under linearly polarized pumping and fast spin exchange near zero magnetic field. Despite the absence of a conservation law for rank-2 angular momentum, our recent experiments reveal anisotropic narrow resonances, hysteresis, and bistability. We attribute these effects to a stretched state forming a collective mode in which orientation and alignment are bidirectionally coupled. This mode acts as a reservoir, preserving the essential properties of alignment despite rapid spin exchange.

physics.atom-ph

$LS/LSJ$ Hybrid Coupling Framework for Auger Angular Distributions of Experimentally Unresolved Multiplets with Isolated Fine-Structure

We present a hybrid $LS/LSJ$ coupling framework for treating state multiplets in the regime $ΔE_\text{int}\sim\hbar/τ_\text{int} \ggΔE_\text{FS}\ggΓ$, where $τ_\text{int}$ is the collision interaction time, $ΔE_\text{FS}$ the fine-structure splitting, and $Γ$ the natural width. In this regime, the collision interaction is fast compared with fine-structure evolution, whereas the individual $J$ levels are well isolated on the scale of their natural widths. The produced multiplet's alignment is therefore described in $LS$ coupling and then projected onto the individual fine-structure $J$ levels before their subsequent decay, described by $LSJ$ coupling. Applied to the multi-open-shell $1s2s2p\,^4\!P_J$ manifold, which closely satisfies these conditions, the hybrid treatment reveals strong suppression and inversion of the Auger angular-distribution anisotropy relative to the traditional pure-$LS$ treatment. It substantially improves agreement with absolute experimental data while using the same $LS$ production cross sections. This hybrid $LS/LSJ$ framework thus provides the appropriate treatment of state multiplets with isolated fine-structure levels, as it retains the $J$-dependent decay dynamics missing from the traditional pure-$LS$ treatment.

physics.atom-ph

Optical Ion Clock with Engineered Immunity to Motion-Induced Frequency Shifts

Spectroscopic frequency shifts due to residual motion of the probed atoms significantly contribute to the uncertainty budgets of state-of-the-art optical ion clocks. For clock transitions with second-order Doppler and quadratic Stark shifts of opposite signs, it is possible to configure electrodynamic ion confinement such that these two shift effects become anticorrelated causing zero net shift. Here, we introduce a spectroscopic interrogation protocol which leads, for systems with unknown and varying motional energy gain rates, to first-order auto-suppression of corresponding frequency shifts without requiring the opposite-sign configuration. We experimentally demonstrate the proposed method on a new ytterbium ion optical clock probing the 467 nm electric octupole (E3) transition, where the combined fractional uncertainty contribution from motion-induced frequency shifts is reduced from $1.3\times10^{-18}$ to $0.3\times10^{-18}$. An interleaved optical frequency ratio measurement against ytterbium's electric quadrupole transition (E2) at 435 nm delivers an E3/E2 frequency ratio of $0.932 \,829 \,404 \,530 \,965 \, 340 (39)$. Combined with previously published ratio data this leads to a limit for a potential fractional temporal variation of the fine-structure constant of $2.4 (2.7) \times 10^{-19}/$yr, in agreement with existing bounds.

physics.atom-ph