Search arXivSearch

arXiv · 1603.07092

Enhanced nonlinear imaging through scattering media using transmission matrix based wavefront shaping

Abstract

Despite the tremendous progresses in wavefront control through or inside complex scattering media, several limitations prevent reaching practical feasibility for nonlinear imaging in biological tissues. While the optimization of nonlinear signals might suffer from low signal to noise conditions and from possible artifacts at large penetration depths, it has nevertheless been largely used in the multiple scattering regime since it provides a guide star mechanism as well as an intrinsic compensation for spatiotemporal distortions. Here, we demonstrate the benefit of Transmission Matrix (TM) based approaches under broadband illumination conditions, to perform nonlinear imaging. Using ultrashort pulse illumination with spectral bandwidth comparable but still lower than the spectral width of the scattering medium, we show strong nonlinear enhancements of several orders of magnitude, through thicknesses of a few transport mean free paths, which corresponds to millimeters in biological tissues. Linear TM refocusing is moreover compatible with fast scanning nonlinear imaging and potentially with acoustic based methods, which paves the way for nonlinear microscopy deep inside scattering media.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hilton B. de Aguiar, Sylvain Gigan, Sophie Brasselet. 2016-03-23. Enhanced nonlinear imaging through scattering media using transmission matrix based wavefront shaping. https://doi.org/10.1103/physreva.94.043830

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mid-infrared reconfiguration of population flow in lanthanide nanocrystals

Converting mid-infrared (MIR) radiation to visible or near-infrared wavelengths is essential for imaging and sensing, yet achieving sensitive, low-power, and scalable detection remains challenging. Lanthanide nanocrystals provide an alternative through ratiometric luminescence but are typically constrained by Boltzmann statistics, which tie population distributions to lattice temperature and limit signal contrast. Here we show that MIR irradiation rebalances dissipative relaxation pathways, driving lanthanide emitters into a non-Boltzmann steady state that enables non-thermal control of population distributions. This allows emission behaviors inaccessible under thermal equilibrium. We exploit this regime to achieve linear MIR detection with respect to MIR power across 6.8 to 8.6 micrometers. The ratiometric response is intrinsically independent of the pump power, enabling operation at an ultralow excitation power of 10 uW, several orders of magnitude lower than conventional approaches. Using standard silicon photodetectors, we then demonstrate room-temperature MIR imaging with detection limits approaching 4 nW um-2. Our results establish lanthanide nanoparticles as an efficient platform for MIR conversion and sensing in nanophotonic systems.

physics.optics

Metasurface-integrated VCSEL designed for polarization control in optical Ising machines

The orthogonal polarization states of vertical-cavity surface-emitting lasers (VCSELs) can be used to describe candidate solutions to the Ising Hamiltonian, which is useful for solving quadratic unconstrained binary optimization problems. However, the natural anisotropy of VCSELs tends to overly favor one polarization state, which impedes the system from working as desired. In this work, we have designed and fabricated a metasurface, which may lead to a VCSEL with reduced undesired anisotropy. By changing the geometric size of nano-structures in the metasurface, the polarization state of the output light can be altered. Based on the injection-locking theory and spin-flip model, we numerically show that VCSELs with lowered anisotropy are more easily affected by the injection locking needed in Ising systems. Additionally, we numerically study the evolution of a 3-bit VCSEL-based Ising system and verify that the computational accuracy of the photonic Ising machine can be improved to more than twice that of its counterpart with higher anisotropy.

physics.optics

Topological Optical Frequency Combs

Optical frequency combs (OFCs) are revolutionary light sources characterized by discrete and equally spaced spectral lines, and they have found widespread applications in metrology, spectroscopy, and communications. In the early stages, OFCs were realized using mode-locked lasers. With advancements in the fabrication of high-quality factor ($Q$) microresonators and the increasing demand for miniaturized and integrable photonic chips, microresonator-based OFCs, commonly referred to as microcombs, have been developed. Although early studies of microcombs primarily focused on single microresonators or a few resonators, a significant breakthrough occurred in 2021 when it was theoretically predicted that light propagating in the topological edge channel of an array of ring resonators could generate nested frequency combs known as topological OFCs. Since then, the field of topological OFCs has progressed rapidly, with experimental observations made in 2024. This Perspective will introduce the history of OFCs, placing particular emphasis on the emergence and development of topological OFCs, as well as exploring the research challenges and opportunities associated with them.

physics.optics