Search arXivSearch

arXiv · 1605.05891

Nonlinear trend removal should be carefully performed in heart rate variability analysis

Abstract

$\bullet$ Background : In Heart rate variability analysis, the rate-rate time series suffer often from aperiodic non-stationarity, presence of ectopic beats etc. It would be hard to extract helpful information from the original signals. 10 $\bullet$ Problem : Trend removal methods are commonly practiced to reduce the influence of the low frequency and aperiodic non-stationary in RR data. This can unfortunately affect the signal and make the analysis on detrended data less appropriate. $\bullet$ Objective : Investigate the detrending effect (linear \& nonlinear) in temporal / nonliear analysis of heart rate variability of long-term RR data (in normal sinus rhythm, atrial fibrillation, 15 congestive heart failure and ventricular premature arrhythmia conditions). $\bullet$ Methods : Temporal method : standard measure SDNN; Nonlinear methods : multi-scale Fractal Dimension (FD), Detrended Fluctuation Analysis (DFA) \& Sample Entropy (Sam-pEn) analysis. $\bullet$ Results : The linear detrending affects little the global characteristics of the RR data, either 20 in temporal analysis or in nonlinear complexity analysis. After linear detrending, the SDNNs are just slightly shifted and all distributions are well preserved. The cross-scale complexity remained almost the same as the ones for original RR data or correlated. Nonlinear detrending changed not only the SDNNs distribution, but also the order among different types of RR data. After this processing, the SDNN became indistinguishable be-25 tween SDNN for normal sinus rhythm and ventricular premature beats. Different RR data has different complexity signature. Nonlinear detrending made the all RR data to be similar , in terms of complexity. It is thus impossible to distinguish them. The FD showed that nonlinearly detrended RR data has a dimension close to 2, the exponent from DFA is close to zero and SampEn is larger than 1.5 -- these complexity values are very close to those for 30 random signal. $\bullet$ Conclusions : Pre-processing by linear detrending can be performed on RR data, which has little influence on the corresponding analysis. Nonlinear detrending could be harmful and it is not advisable to use this type of pre-processing. Exceptions do exist, but only combined with other appropriate techniques to avoid complete change of the signal's intrinsic dynamics. 35 Keywords $\bullet$ heart rate variability $\bullet$ linear / nonlinear detrending $\bullet$ complexity analysis $\bullet$ mul-tiscale analysis $\bullet$ detrended fluctuation analysis $\bullet$ fractal dimension $\bullet$ sample entropy;

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Binbin Xu, Rémi Dubois, Oriol Pont, Hussein Yahia. 2016-05-19. Nonlinear trend removal should be carefully performed in heart rate variability analysis. https://arxiv.org/abs/1605.05891

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High Reconstruction Quality and Restart Repeatability Do Not Guarantee Recovery of Ground-Truth Muscle Synergies

High reconstruction quality and agreement across repeated fits do not necessarily establish recovery of muscle synergies. We tested whether a variance-accounted-for (VAF)/elbow rule recovers the generating synergy count and spatial vectors, whether high restart repeatability indicates recovery, and how five design factors affect recovery. Non-negative matrix factorisation was applied to 4,320 synthetic 16-muscle datasets varying generating rank, noise, trial count, spatial similarity and activation overlap. Combined recovery required the correct rank and cosine similarity of at least 0.80 for every matched spatial vector. Factor effects and two-factor interactions were assessed using exploratory heteroscedastic Wald tests with Benjamini-Hochberg adjustment. Rank selection was exact in 17.6% of datasets, too low in 54.9% and too high in 27.5%; combined recovery was 13.9%. Among fits with VAF at least 0.90, only 11.3% achieved combined recovery. Among 3,762 datasets with spatial repeatability at least 0.95, 19.6% had the correct rank and 15.7% achieved combined recovery. All five factors were associated with recovery (adjusted p < 0.001). Recovery declined from 26.2% to 1.7% with increasing spatial similarity and from 26.2% to 2.2% with increasing activation overlap. It was lower at ranks 7-9 than at 3-5, increased from 11.0% with 3 trials to 15.8% with 80 trials, and varied non-monotonically with noise. Five noiseless signals synthesised from measured-sEMG reference factors also showed under-selection despite VAF above 0.918. Under this selector, high reconstruction quality and restart agreement were insufficient indicators of correct rank and spatial recovery. Muscle-synergy interpretation should account for rank sensitivity and the separability of spatial and activation patterns.

q-bio.QM

A hierarchical memory architecture overcomes context limits in long-horizon multi-agent computational modeling

Large language models (LLMs) demonstrate remarkable reasoning capabilities, yet their stateless architecture fundamentally limits deployment in long-horizon research workflows requiring multi-session continuity and quantitative rigor. Here we present Ensemble QSP, a multi-agent framework featuring a three-layer hierarchical memory architecture that bounds injected context (median 301 tokens, max 4,050) by capping state categories and evicting completed work. This enables continuous autonomous operation without context degradation. The system orchestrates five specialist worker agents under domain-expert principal investigators (PIs), enforcing physical constraints through physics-based checklists and structured domain knowledge. Comprehensive benchmarking demonstrates autonomous pharmacokinetic-pharmacodynamic (PKPD) model selection, improved parameter recovery relative to single-agent baselines, and robust interpretation of linguistically diverse prompts. Replication with open-weight models (DeepSeek-V4-Flash/Pro, Llama 3.1 70B) confirmed these architectural conclusions across PKPD modeling, literature synthesis, and PBPK model implementation, proving the framework is independent of proprietary LLMs. Feature-level ablations show that memory, retrieval, and PI oversight address distinct scientific failure modes, though underlying LLM capability remains consequential for stringent physical-consistency checks. The architecture is structurally agnostic to computational biology; adding a new scientific domain requires only a new PI-agent configuration.

q-bio.QM

Hierarchical Maximum Likelihood Estimation for Time-Resolved NMR Data

Metabolic monitoring and reaction rate estimation using hyperpolarized NMR technology requires accurate quantitative analysis of multidimensional data scenarios. Currently, this analysis is often performed in a two-stage procedure, which is prone to errors in uncertainty propagation and estimation. We propose an approach derived from a Bayesian hierarchical model that intrinsically propagates uncertainties and operates on the full data to maximize the precision at minimal uncertainty. In an analytic treatment, we reduce the estimation procedure to a least-squares optimization problem which can be understood as an extension of the Variable Projection (VarPro) approach for data scenarios with two predictors. We investigate the method's efficacy in two experiments with hyperpolarized metabolites recorded with conventional high-field NMR devices and a micronscale NMR setup using Nitrogen-Vacancy centers in diamond for detection, respectively. In both examples, the new approach improves estimates compared to Fourier methods and proves operational advantages over a two-stage procedure employing VarPro. While the approach presented is motivated by NMR analysis, it is straightforwardly applicable to further estimation scenarios with similar data structure, such as time-resolved photospectroscopy.

q-bio.QM