arXiv · 1612.06442
Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm
Abstract
PURPOSE: Establishing and obtaining consistent quantitative indices of retinal thickness from a variety of clinically used Spectral-Domain Optical Coherence Tomography scanners. DESIGN: Retinal images from five Spectral-Domain Optical Coherence Tomography scanners were used to determine total retinal thickness with scanner-specific correction factors establishing consistency of thickness measurement across devices. PARTICIPANTS: 55 Fovea-centered Spectral-Domain Optical Coherence Tomography volumes from eleven subjects were analyzed, obtained from Cirrus HD-OCT, RS-3000, Heidelberg Spectralis, RTVue and Topcon2000, seven subjects with retinal diseases and four normal controls. METHOD: The Iowa Reference Algorithm measured total retinal thickness. Nonlinear model of total retinal thickness measurement comparisons was derived and used for device-specific comparisons. Bland-Altman plots and pairwise predictive equations yielded pairwise scanner-specific differences. Mendel test determined whether measurement biases were constant for each scanner pair. RESULTS: Mendel test revealed that all pairwise scanner differences of total retinal thickness were constant across the cohort (p=0.992). Individual measurements can thus be bias-corrected and the Iowa Reference Algorithm serve as a scanner-agnostic independent standard of total retinal thickness across the five tested SD-OCT scanners. CONCLUSIONS: Combination of the Iowa Reference Algorithm with scanner-specific bias correction yields cross-scanner consistency of total retinal thickness measurements, facilitating scanning-device independent quantitative assessment of total retinal thickness, longitudinal follow-up quantification without requiring patients to be imaged on the same scanner model, and allowing for multi-center studies with heterogeneous device utilization when using the Iowa Reference Algorithm.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Adnan Rashid, Sebastian M. Waldstein, Bianca S. Gerendas, Hrvoje Bogunovic, Andreas Wahle, Kyungmoo Lee, Kai Wang, Christian Simader, Michael D. Abramoff, Ursula Schmidt-Erfurth, Milan Sonka. 2016-12-19. Reproducibility of Retinal Thickness Measurements across Spectral-Domain Optical Coherence Tomography Devices using Iowa Reference Algorithm. https://arxiv.org/abs/1612.06442
Cite the original work for its findings. Save a collection to share your selection of sources.