Near optimal neural network estimator for spectral x-ray photon counting data with pileup

Abstract

-Purpose: A neural network estimator to process x-ray spectral measurements from photon counting detectors with pileup. The estimator is used with an expansion of the attenuation coefficient as a linear combination of functions of energy multiplied by coefficients that depend on the material composition at points within the object [R.E. Alvarez and A. Macovski, Phys. Med. Biol., 1976, 733-744]. The estimator computes the line integrals of the coefficients from measurements with different spectra. Neural network estimators are trained with measurements of a calibration phantom with the clinical x-ray system. One estimator uses low noise training data and another network is trained with data computed by adding random noise to the low noise data. The performance of the estimators is compared to each other and to the Cramer-Rao lower bound (CRLB). Methods: The estimator performance is measured using a Monte Carlo simulation with an idealized model of a photon counting detector that includes only pileup and quantum noise. Transmitted x-ray spectra are computed for a calibration phantom. The transmitted spectra are used to compute random data for photon counting detectors with pileup. Detectors with small and large dead times are considered. Neural network training data with extremely low noise are computed by averaging the random detected data with pileup for a large numbers of exposures of the phantom. Each exposure is equivalent to a projection image or one projection of a computed tomography scan. Training data with high noise are computed by using data from one exposure. Finally, training data are computed by adding random data to the low noise data. The added random data are multivariate normal with zero mean and covariance equal to the sample covariance of data for an object with properly chosen attenuation. To test the estimators, random data are computed for different thicknesses of three test objects with different compositions. These are used as inputs to the neural network estimators. The mean squared errors (MSE), variance and square of the bias of the neural networks' outputs with the random object data are each compared to the CRLB. Results: The MSE for a network trained with low noise data and added noise is close to the CRLB for both the low and high pileup cases. Networks trained with very low noise data have low bias but large variance for both pileup cases. ralvarez@aprendtech.com Networks trained with high noise data have both large bias and large variance. Conclusion: With a properly chosen level of added training data noise, a neural network estimator for photon counting data with pileup can have variance close to the CRLB with negligible bias.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert Alvarez. 2017-02-03. Near optimal neural network estimator for spectral x-ray photon counting data with pileup. https://arxiv.org/abs/1702.01006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.

physics.med-ph

On phase aberration estimation using common mid-angle speckle correlations

Phase aberrations, despite degrading ultrasound images, also encode valuable information about the spatial distribution of the speed of sound in tissue. In pulse-echo ultrasound, we can quantify them by exploiting speckle correlations. Among existing strategies, correlations between steered acquisitions that share a common mid-angle have proven particularly effective for inferring the speed of sound. Their phases can be linearly related to the phase aberrations undergone by both the incident and reflected wavefronts. This relationship has so far been demonstrated only through geometric arguments based on point reflectors. Here, we develop a rigorous theoretical formalism that extends this relationship to the speckle regime, completing the previously established linear model and clarifying its underlying assumptions. More importantly, we build on this formalism to analyze correlation-phase fluctuations arising from aberration-induced speckle decorrelation. The analysis reveals that phase variance is governed by the relative loss of coherence, which increases approximately linearly with the square of the correlation phases. Local correlation-phase estimates therefore become increasingly uncertain as their magnitude grows. Experimental measurements in a uniform tissue-mimicking phantom show excellent agreement with the predicted variance. Beyond providing a theoretical basis for advancing speed-of-sound imaging, this formalism establishes the accuracy limit of common-mid-angle correlation phases, offering a benchmark for evaluating more advanced aberration-estimation techniques.

physics.med-ph

Buccal-Lingual Analysis and Inflammation Tracking in Oral Soft Tissues Using Quantitative Ultrasound: A Preclinical Study

Four out of 10 adults aged 30 years or older in the USA are impacted by periodontal diseases which span a spectrum of inflammatory conditions. Currently, a subjective, invasive and a semi-quantitative approach, termed bleeding on probing, is employed in clinics for inflammation assessment. The long-term goal of this study is to fill the current clinical diagnostic gap in dentistry by proposing quantitative ultrasound (QUS)-based biomarkers for inflammation diagnosis and monitoring. Here, as one of the early works in this area, we investigated two QUS parameters for characterizing periodontal inflammation in gingival tissues using a longitudinal preclinical porcine study: attenuation coefficient slope (ACS) and backscatter intensity (BSI). Our study included eight pigs imaged intraorally (24 MHz) at four bi-weekly timepoints from week 0 (healthy) to week 6 (post inflammation inoculation) at their interproximal sites of the third premolars (PM3-Mes) from all quadrants. Moreover, we compared gingival tissues surrounding a tooth at lingual/palatal side versus buccal side at the second molar (M2-Dis) in healthy condition. Our results showed that gingival ACS at all inflammation timepoints were significantly lower than healthy gingival ACS (1.69 \pm 0.53 dB/cm.MHz) using a mixed effect analysis (week 6: 1.08 \pm 0.25 dB/cm.MHz). Longitudinal comparison of BSI did not demonstrate any statistical significance. Gingival ACS and BSI at lingual/palatal versus buccal sides of M2-Dis did not exhibit any statistical significance. These ACSs were linearly correlated with R-squared = 0.89 and a correlation slope of 0.87. For BSI, Bland-Altman analysis demonstrated no difference in mean BSI, although variability was high. These findings highlight the promising potential of ultrasonography paired with QUS to complement current standard of care in dentistry.

physics.med-ph