Search arXivSearch

arXiv · 1703.01929

Stable dynamics of micro-machined inductive contactless suspensions

Abstract

In this article, we present a qualitative approach to study the dynamics and stability of micro-machined inductive contactless suspensions (MIS). In the framework of this approach, the induced eddy current into a levitated micro-object is considered as a collection of m-eddy current circuits. Assuming small displacements and the quasi- static behaviour of the levitated micro-object, a generalized model of MIS is obtained and represented as a set of six linear differential equations corresponding to six degrees of freedom in a rigid body by using Lagrange-Maxwell formalism. The linear model allows us to investigate the general stability properties of the MIS as a dynamic system, and these properties are synthesized in three major theorems. In particular, we prove that the stable levitation in the MIS without damping is impossible. Based on the approach presented herewith, we give general guidelines for MIS designing. In addition to we demonstrate the successful application of this technique to study the dynamics and stability of the symmetric and axially symmetric MIS designs both based on 3D micro-coil technology.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kirill V Poletkin, Zhiqiu Lu, Ulrike Wallrabe, Jan Korvink, Vlad Badilita. 2017-08-10. Stable dynamics of micro-machined inductive contactless suspensions. https://doi.org/10.1016/j.ijmecsci.2017.08.016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det