Interactive reconstructions of cranial 3D implants under MeVisLab as an alternative to commercial planning software

Abstract

In this publication, the interactive planning and reconstruction of cranial 3D Implants under the medical prototyping platform MeVisLab as alternative to commercial planning software is introduced. In doing so, a MeVisLab prototype consisting of a customized data-flow network and an own C++ module was set up. As a result, the Computer-Aided Design (CAD) software prototype guides a user through the whole workflow to generate an implant. Therefore, the workflow begins with loading and mirroring the patients head for an initial curvature of the implant. Then, the user can perform an additional Laplacian smoothing, followed by a Delaunay triangulation. The result is an aesthetic looking and well-fitting 3D implant, which can be stored in a CAD file format, e.g. STereoLithography (STL), for 3D printing. The 3D printed implant can finally be used for an in-depth pre-surgical evaluation or even as a real implant for the patient. In a nutshell, our research and development shows that a customized MeVisLab software prototype can be used as an alternative to complex commercial planning software, which may also not be available in every clinic. Finally, not to conform ourselves directly to available commercial software and look for other options that might improve the workflow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jan Egger, Markus Gall, Alois Tax, Muammer Ücal, Ulrike Zefferer, Xing Li, Gord von Campe, Ute Schäfer, Dieter Schmalstieg, Xiaojun Chen. 2017-03-09. Interactive reconstructions of cranial 3D implants under MeVisLab as an alternative to commercial planning software. https://doi.org/10.1371/journal.pone.0172694

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Conceptualization of electronic dose to water and water-equivalent gas for ionometric dosimetry in external beam radiotherapy

Electronic dose to water, which is the radiant energy imparted to a unit mass of water by electronic collisions, is conceptualized to exclude corrections and uncertainties associated with energy transfer to atomic nuclei and to enhance medical relevance in radiotherapy dosimetry. Based on the international code of practice, the procedures to determine electronic doses were formulated for high-energy photon, electron, proton, and ion beams. Nitrogen-based water-equivalent gas (WEG) mixtures were designed for use in gas-sealed ionization chambers for proton and ion beams. A thought experiment of reference dosimetry for electronic dose demonstrated its compatibility with absorbed dose for photon and electron beams. For proton and ion beams, the transition from absorbed dose to electronic dose will change the measured dose values by -1.4% and -2.2%, and decrease the uncertainty from 1.6% to 1.5% and from2.6% to 2.1%, respectively. With WEG ionization chambers, the uncertainty will further decrease to 1.2% for proton beams and 1.5% for ion beams. The formulated framework will be applicable to radiotherapy dosimetry with traceable dosimeter calibration under the international measurement system for radiation metrology.

physics.med-ph

A novel methodology to estimate pileup effects and induced error in microdosimetric spectra

Microdosimetry provides a superior characterization of the radiation field compared to conventional LET-based methodology, and for this reason it has become increasingly attractive for quality assurance in particle therapy. However, the typical particle rates used in the treatments lead to pileup, which distorts the experimental spectra, and thus compromises the accuracy of microdosimetric measurements, limiting their use in clinical settings. In this work, we investigated the pileup in a spherical Tissue Equivalent Proportional Counter (TEPC), and developed an algorithm to evaluate the contribution of this effect to the measured spectra. We exposed the TEPC to 11 and 70 MeV proton beams, and collected the microdosimetric spectra at rates in the $10^3$-$10^6$ pps range. Using a combination of GEANT4 Monte Carlo simulations and experimental data, we develop an algorithm capable of estimating the pileup probability affecting experimental measurements. The data suggest that the pileup probability has a linear increase with rate until it reaches a value of $15 \pm 3 \, \%$ at $28.2 \times 10^3$ pps, at which point it begins to saturate. Additionally, the outcomes from the comparison of the two proton energies suggest that the methodology used to estimate pileup can be used to predict the effects in clinical proton beams with similar energies. This same methodology can be applied to any type of microdosimetric measurement making it a reliable tool for addressing pileup issues and facilitating the application of microdosimetry in clinical settings.

physics.med-ph