Search arXivSearch

arXiv · 1705.04967

Combined narrowband imager-spectrograph with volume-phase holographic gratings

Abstract

In the present work we discuss a possibility to build an instrument with two operation modes - spectral and imaging ones. The key element of such instrument is a dispersive and filtering unit consisting of two narrowband volume-phase holographic gratings. Each of them provides high diffraction efficiency in a relatively narrow spectral range of a few tens of nanometers. Besides, the position of this working band is highly dependent on the angle of incidence. So we propose to use a couple of such gratings to implement the two operational modes. The gratings are mounted in a collimated beam one after another. In the spectroscopic mode the gratings are turned on such angle that the diffraction efficiency curves coincide, thus the beams diffracted on the first grating are diffracted twice on the second one and a high-dispersion spectrum in a narrow range is formed. If the collimating and camera lenses are corrected for a wide field it is possible to use a long slit and register the spectra from its different points separately. In the imaging mode the gratings are turned to such angle that the efficiency curves intersect in a very narrow wavelength range. So the beams diffracted on the first grating are filtered out by the second one except of the spectral component, which forms the image. In this case the instrument works without slit diaphragm on the entrance. We provide an example design to illustrate the proposed concept. This optical scheme works in the region around 656 nm with F/# of 6.3. In the spectroscopic mode it provides a spectrum for the region from 641 to 671 nm with reciprocal linear dispersion of 1.4 nm/mm and the spectral resolving power higher than 14000. In the imaging mode it covers linear 12mm x 12mm field of view with spatial resolution of 15-30 lines/mm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eduard R. Muslimov, Sergei N. Fabrika, Gennady G. Valyavin. 2017-05-14. Combined narrowband imager-spectrograph with volume-phase holographic gratings. https://arxiv.org/abs/1705.04967

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Scale-Vector Alignment: A Scale-Aware Framework for Spatially Resolved Morphological Similarity in Astronomical Images

Astronomical maps made with different tracers are not expected to have identical morphology. Excitation, optical depth, chemistry, radiation, and ISM phase alter the response of a tracer, and the resulting differences can depend on both position and spatial scale. We propose scale-vector alignment, a scale-aware method based on Constrained Diffusion Decomposition (CDD). CDD decomposes an image into localized scale components; at each position, their amplitudes define a scale vector that describes how the measured intensity is distributed over spatial scale. We define the pixel-wise similarity $\Spix(x,y)$ as the normalized alignment of two local scale vectors. The normalization removes the overall amplitude, so $\Spix$ compares relative scale composition rather than absolute flux. We also define the scale-wise similarity $\Sscale(l)$ by comparing the two CDD component maps at each spatial scale. Spatial shifts are used to construct an empirical shifted reference distribution for $\Spix$. In Orion~A, the tracer with the highest similarity to the dust-derived column-density map changes from $^{12}$CO to $^{13}$CO to C$^{18}$O toward higher column density. In NGC~6334I(N), the line--continuum similarity decreases locally around the brightest compact structures, where radiative-transfer effects can alter the observed line morphology. In NGC~3627, CO is most similar to 21~$μ$m emission, and $\Sscale$ reaches its maximum at an intermediate sub-kpc scale. The method measures where two tracers have similar multiscale structure and at which scales their spatial distributions agree. The implementation is publicly available at https://github.com/meng-ke/Scale-Vector-Alignment.

astro-ph.IM

Fast and accurate astronomical source deblending with Density-Peak Clustering

Source deblending is a fundamental challenge for current and forthcoming astronomical surveys, where increasing source density and image depth lead to a growing number of overlapping detections. Accurate deblending is essential for reliable measurements of source morphology and photometry, as well as for cosmological analyses. We present a redesign of the Advanced Density Peak (ADP) clustering algorithm, tailored to the identification and separation of blended astronomical sources within detection regions. We develop a validation framework combining realistic image simulations, automatically generated ground-truth segmentation, and label-invariant metrics. ADP is assessed against ASTErIsM, an established density-based astronomical deblender, using pairwise simulations, synthetic multi-source images, and Euclid Q1 public data. In pairwise simulations, the methods show comparable performance across a broad range of source separations and flux ratios, with photometric differences typically below 1% and reaching 5-7% in the most challenging cases, without systematic bias. In multi-source simulations, ADP recovers approximately 8% more ground-truth sources, while the positions of sources identified by both methods agree at the sub-pixel level. On Euclid Q1 public data, the methods show strong agreement in segmentation area, ellipticity, position angle, and photometry, with the largest differences for the smallest and faintest sources. ADP also provides a substantial computational advantage: end-to-end benchmarks on 19200 x 19200 pixel Euclid images require approximately 16-200 s, corresponding to speedups of 12-156x relative to ASTErIsM, with median and mean improvements of 36x and 54x, respectively. These results show that ADP provides scientifically competitive deblending at substantially lower computational cost, making it a promising approach for large-scale astronomical imaging surveys.

astro-ph.IM

IceCube Upgrade status and perspectives

The IceCube Neutrino Observatory instruments one cubic kilometer of deep-glacial ice between 1450 m and 2450 m below the surface at the geographic South Pole to detect neutrinos via Cherenkov radiation of relativistic charged particles produced in their interactions. This detector is responsible for a number of key observations in neutrino astrophysics, which include the discovery of a high-energy astrophysical neutrino flux and, more recently, the galactic plane. During the austral summer of 2025/26, five new strings equipped with new photosensor designs were deployed as a dense infill in the middle of the existing detector. The science goals of this detector are twofold: Firstly, given the higher photocathode density, an improved atmospheric neutrino event selection and reconstruction at a few GeV can be achieved for enhanced capabilities to study neutrino oscillations. Secondly, novel calibration devices will improve the knowledge of the optical properties of the glacial ice and the detector response. These new calibration results will be applied to archival IceCube data, improving angular and spatial resolution of all detected astrophysical neutrino events. The IceCube Upgrade also serves as a first step towards the next-generation neutrino telescope at the South Pole, called IceCube-Gen2.

astro-ph.IM