A white neutron beam line using the back-streaming neutrons from the spallation target at China Spallation Neutron Source (CSNS) is under construction. Different spectrometers mainly for nuclear data measurements to be installed in the so-called Back-n beam line are also under development in phases. The physics design of the beam line includes the overview of the characteristics of the neutron beam including energy spectrum, flux and time structure, and the optimizations of neutron beam spots and in-hall background with the help of a complicated collimation system and a sophisticated neutron dump. The wide neutron energy range of 1 eV~100 MeV is very good to support different applications, especially for nuclear data measurements. At Endstation#2 where is about 80 m from the target, the main properties include neutron flux of 106 n/cm2/s, time resolution of a few per mille over almost the whole energy range, in-hall background about 0.01 /cm2/s for both neutron and gamma. With its completion in late 2017, Back-n will be not only the first high-performance white neutron source in China, but also among the best white neutron sources in the world.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L. Y. Zhang, H. T. Jing, J. Y. Tang, Q. Li, X. C. Ruan, J. Ren, C. J. Ning, Y. J. Yu, Z. X. Tan, P. C. Wang, Y. C. He, X. Q. Wang. 2017-11-14. Design of back-streaming white neutron beam line at CSNS. https://arxiv.org/abs/1707.00292

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det