Search arXivSearch

arXiv · 1708.00713

Light polarization measurements in tests of macrorealism

Abstract

According to the world view of macrorealism, the properties of a given system exist prior to and independent of measurement, which is incompatible with quantum mechanics. Leggett and Garg put forward a practical criterion capable of identifying violations of macrorealism, and so far experiments performed on microscopic and mesoscopic systems have always ruled out in favor of quantum mechanics. However, a macrorealist can always assign the cause of such violations to the perturbation that measurements effect on such small systems, and hence a definitive test would require using non-invasive measurements, preferably on macroscopic objects, where such measurements seem more plausible. However, the generation of truly macroscopic quantum superposition states capable of violating macrorealism remains a big challenge. In this work we propose a setup that makes use of measurements on the polarization of light, a property which has been extensively manipulated both in classical and quantum contexts, hence establishing the perfect link between the microscopic and macroscopic worlds. In particular, we use Leggett-Garg inequalities and the criterion of no-signaling in time to study the macrorealistic character of light polarization for different kinds of measurements, in particular with different degrees of coarse-graining. Our proposal is non-invasive for coherent input states by construction. We show for states with well defined photon number in two orthogonal polarization modes, that there always exists a way of making the measurement sufficiently coarse-grained so that a violation of macrorealism becomes arbitrarily small, while sufficiently sharp measurements can always lead to a significant violation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eugenio Roldán, Johannes Kofler, Carlos Navarrete-Benlloch. 2017-08-02. Light polarization measurements in tests of macrorealism. https://doi.org/10.1103/physreva.97.062117

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Iteratively decoded magic state distillation

We present numerical simulation results for the 7-to-1 and 15-to-1 state distillation circuits, constructed using transversal CNOTs acting on multiple surface code patches. The distillation circuits are decoded iteratively using the method outlined in [arXiv:2407.20976]. We show that, with a re-configurable qubit architecture, we can perform fast magic state distillation in $\sim\mathcal{O}(1)$ code cycles. We confirm that both circuits suppress an injected input logical error rate $p$ to $\mathcal{O}(p^3)$ in the presence of additional circuit-level noise. This is done with two types of stabiliser proxies, distilling logical $|-\rangle$ and $|Y\rangle$ states, the latter is the intended state of the 7-to-1 circuit while a stabiliser-proxy for the 15-to-1 circuit. We then also provide numerical evidences for actual $|T\rangle$ state distillation using the 15-to-1 circuit with a faulty-$T$ measurement, leveraging recent near-Clifford simulation tools. Finally, we outline how ZX-calculus and Pauli webs can be used to benchmark stabiliser proxies for these distillation circuits.

quant-ph

Enhanced measurements on quantum computers via the simultaneous probing of non-commuting Pauli operators

Measuring the state of quantum computers is a highly non-trivial task, with implications for virtually all quantum algorithms. A promising avenue is multi-copy schemes, where identical copies of a quantum state are measured jointly so that all Pauli operators within the considered observable can be simultaneously assessed. Here, we present a first implementation of such a two-copy scheme in a measurement protocol. Based on Bayesian statistics, it accurately estimates not only the average of the desired observable but also the error en route. This enables an adaptive shot-allocation algorithm that preferentially samples the most uncertain Pauli terms. In regimes with many non-commuting Pauli operators, this ``double'' scheme can outperform the state-of-the-art measurement protocol in minimizing total shots for a given precision. We also numerically confirm the finding in previous theoretical works that the two-copy scheme incurs an overhead due to the square-root relationship between the variance of measured quantities and the number of measurement shots.

quant-ph

Thermodynamics of a phaseonium-driven optomechanical Otto engine

We study an optomechanical Otto engine whose working medium is a single-mode cavity driven by beams of coherently prepared three-level phaseonium atoms. The atoms are not thermal reservoirs in the Gibbs sense; rather, their populations and ground-state coherence set the detailed-balance ratio of the cavity collision map, so that the field relaxes to a Gibbs state at an operational apparent temperature. We combine the finite-time collision-model dynamics with radiation-pressure work extraction and compare three reservoir preparations: a thermal reference at the same apparent temperatures, an incoherent atomic beam with the same populations, and the coherent phaseonium beam. We show that the phaseonium isochore charges the cavity passively: the cavity ergotropy and energy-basis coherence remain zero up to numerical precision, while the state converges to the Gibbs fixed point selected by the apparent detailed balance. We further estimate lower bounds on the cost of preparing the atomic populations and coherence, showing that the relevant advantage of phaseonium is a resource-preparation tradeoff rather than a cost-free enhancement over a thermal bath at the same temperature. Finally, we assess the finite-time performance of a two-cavity cascade with additive mechanical work accounting. Over the investigated coherence-phase range, the cascade produces approximately $47\%$--$52\%$ more power than the single-cavity engine while requiring only $65\%$--$68\%$ of the hot and cold phaseonium atoms needed by two independent engines, resulting in a $9\%$--$15\%$ enhancement of power per injected atom over a complete cycle.

quant-ph