arXiv · 1708.08535
Radon Mitigation for the SuperCDMS SNOLAB Dark Matter Experiment
Abstract
A potential background for the SuperCDMS SNOLAB dark matter experiment is from radon daughters that have plated out onto detector surfaces. To reach desired backgrounds, understanding plate-out rates during detector fabrication as well as mitigating radon in surrounding air is critical. A radon mitigated cleanroom planned at SNOLAB builds upon a system commissioned at the South Dakota School of Mines & Technology (SD Mines). The ultra-low radon cleanroom at SD Mines has air supplied by a vacuum-swing-adsorption radon mitigation system that has achieved $>$1000$\times$ reduction for a cleanroom activity consistent with zero and $<0.067\,$Bq$\,$m$^{-3}$ at 90% confidence. Our simulation of this system, validated against calibration data, provides opportunity for increased understanding and optimization for this and future systems.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
J. Street, R. Bunker, E. H. Miller, R. W. Schnee, S. Snyder, J. So. 2017-08-28. Radon Mitigation for the SuperCDMS SNOLAB Dark Matter Experiment. https://doi.org/10.1063/1.5018995
Cite the original work for its findings. Save a collection to share your selection of sources.