Search arXivSearch

arXiv · 1711.07470

Theory and Practice of Electron Diffraction from Single Atoms and Extended Objects using an Electron Microscope Pixel Array Detector

Abstract

What does the diffraction pattern from a single atom look like? How does it differ from the scattering from long range potential? With the development of new high-dynamic range pixel array detectors to measure the complete momentum distribution, these questions have immediate relevance for designing and understanding momentum-resolved imaging modes. We explore the asymptotic limits of long range and short range potentials. We use a simple quantum mechanical model to explain the general and asymptotic limits for the probability distribution in both and real and reciprocal space. Features in the scattering potential much larger than the probe size cause the bright-field disk to deflect uniformly, while features much smaller than the probe size, instead of a deflection cause a redistribution of intensity within the bright-field disk. Because long range and short range features are encoded differently in the diffraction pattern, it is possible to separate their contributions in differential phase contrast (DPC) or Center-of-Mass (CoM) imaging. The shape profiles for atomic resolution CoM imaging are dominated by the shape of the probe gradient and not the highly-singular atomic potentials or their local fields. Instead, only the peak height shows an atomic-number sensitivity, whose precise dependence is determined by the convergence angle. At lower convergence angles, the contrast oscillates with increasing atomic number, similar to bright field imaging. The range of collection angles impacts DPC and CoM imaging differently, with CoM being more sensitive to the upper cutoff limit, while DPC is more sensitive to the lower cutoff.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael C. Cao, Yimo Han, Zhen Chen, Yi Jiang, Kayla X. Nguyen, Emrah Turgut, Greg Fuchs, David A. Muller. 2017-11-22. Theory and Practice of Electron Diffraction from Single Atoms and Extended Objects using an Electron Microscope Pixel Array Detector. https://doi.org/10.1017/s1431927617002902

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det