Search arXivSearch

arXiv · 1712.05700

Simulation Study of Energy Resolution with Changing Pixel Size for Radon Monitor Based on \textit{Topmetal-${II}^-$} TPC

Abstract

In this paper, we study how pixel size influences energy resolution for a proposed pixelated detector---a high sensitivity, low cost, and real-time radon monitor based on \textit{Topmetal-${II}^-$} time projection chamber (TPC). Using \textit{Topmetal-${II}^-$} sensors assembled by 0.35 $μ$m CMOS Integrated Circuit process, this monitor is designed to improve the spatial resolution of detecting radon alpha particles. Concerning small pixel size might has a side effect of worsening energy resolution due to lower signal to noise ratio, a Great4-based simulation is used to figure out energy resolution dependence on pixel size ranging from 60 $μ$m to 600 $μ$m. A non-monotonic trend in this region shows a combination effect of pixel size with threshold on pixel, and is analyzed by introducing an empirical expression. Noise on pixel contributes 50 keV Full Width at Half Maximum (FWHM) energy resolution for 400 $μ$m pixel size at 1 $\sim$ 4 $σ$ threshold, which is comparable to the energy resolution caused by energy fluctuation in ionization process of TPC ($\sim$ 20 keV). The total energy resolution after combining both factors is estimated to be 54 keV for 400 $μ$m pixel size at 1 $\sim$ 4 $σ$ threshold. The analysis presented in this paper is helpful to choosing suitable pixel size for future pixelated detectors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mengyao Huang, Hua Pei, Xiangming Sun, Shuguang Zou. 2019-01-05. Simulation Study of Energy Resolution with Changing Pixel Size for Radon Monitor Based on \textit{Topmetal-${II}^-$} TPC. https://doi.org/10.1007/s41365-018-0532-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det