Search arXivSearch

arXiv · 1712.06694

Single-particle Mass Spectrometry with arrays of frequency-addressed nanomechanical resonators

Abstract

One of the main challenges to overcome to perform nanomechanical Mass Spectrometry (NEMS-MS) analysis in a practical time frame stems from the size mismatch between the analyte beam and the extremely small nanomechanical detector area. We report here the demonstration of NEMS-MS with arrays of 20 individually addressed nanomechanical resonators where the number of inputs-outputs for the whole array is the same as that of a single resonator. While all resonators within an array are interconnected via two metal levels, each resonator is designed with a distinct resonance frequency which becomes its individual address. In order to perform single-particle Mass Spectrometry, the resonance frequencies of the two first modes of each NEMS within an array are monitored simultaneously. Using such an array, mass spectra of metallic aggregates in the MDa range are acquired with more than one order of magnitude improvement in analysis time due to the increase in capture cross section compared to individual resonators. A 20 NEMS array is probed in 150ms with the same mass limit of detection as a single resonator. Spectra acquired with a conventional Time- of-Flight (TOF) mass spectrometer in the same system show excellent agreement. As individual information for each resonator within the array is retained, the array becomes a particle imager, each resonator acting as a pixel. With this technique, we demonstrate how Mass Spectrometry Imaging (MSI) at the single particle level becomes possible by mapping a 4cm-particle beam in the MDa range and above.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eric Sage, Marc Sansa, Shawn Fostner, Martial Defoort, Marc Gély, Akshay K. Naik, Robert Morel, Laurent Duraffourg, Michael L. Roukes, Thomas Alava, Guillaume Jourdan, Eric Colinet, Christophe Masselon, Ariel Brenac, Sébastien Hentz. 2017-12-12. Single-particle Mass Spectrometry with arrays of frequency-addressed nanomechanical resonators. https://doi.org/10.1038/s41467-018-05783-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det