Search arXivSearch

arXiv · 1712.09039

Motionless and fast measurement technique for obtaining the spectral diffraction efficiencies of a grating

Abstract

The measurement of the spectral diffraction efficiencies of a diffraction grating is essential for improving the manufacturing technique and for assessing the grating's function in practical applications. The drawback of the currently popular measurement technique is its slow speed due to the hundreds of repetitions of two kinds of time-consuming mechanical movements during the measuring process (i.e., the rotation of the mechanical arm to capture the light beam, and the mechanical variation of the output wavelength of the grating monochromator). This limitation greatly restricts the usage of this technique in dynamic measurement. In this manuscript, we present a motionless and fast measurement technique for obtaining the spectral diffraction efficiencies of a plane grating, effectively eliminating the aforementioned two kinds of mechanical movement. Herein, the proposed solution for removing the first kind of mechanical movement is tested, and the experimental result shows that the proposed method can be successfully used to measure the plane transmission grating's spectral diffraction efficiencies in the wavelength range of 550-750 nm. The method for eliminating the second kind of mechanical movement is not verified in this manuscript; however, we think that it is very straightforward and commercially available. We estimate that the spectral measurement can be achieved on a millisecond timescale by combining the two solutions. Our motionless and fast measuring technique will find broad applications in dynamic measurement environments and mass industrial testing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shenghao Wang, Shijie Liu, Jianda Shao, Yonglu Wang, Fanyu Kong, Yunxia Jin. 2018-06-19. Motionless and fast measurement technique for obtaining the spectral diffraction efficiencies of a grating. https://doi.org/10.1063/1.5030069

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det