arXiv · 1802.09274
Laser frequency stabilization using a commercial wavelength meter
Abstract
We present the characterization of a laser frequency stabilization scheme using a state-of-the-art wavelength meter based on solid Fizeau interferometers. For a frequency-doubled Ti-sapphire laser operated at 461 nm, an absolute Allan deviation below $10^{-9}$ with a standard deviation of $1$ MHz over 10\,h is achieved. Using this laser for cooling and trapping of strontium atoms, the wavemeter scheme provides excellent stability in single-channel operation. Multi-channel operation with a multimode fiber switch results in fluctuations of the atomic fluorescence correlated to residual frequency excursions of the laser. The wavemeter-based frequency stabilization scheme can be applied to a wide range of atoms and molecules for laser spectroscopy, cooling and trapping.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Luc Couturier, Ingo Nosske, Fachao Hu, Canzhu Tan, Chang Qiao, Y. H. Jiang, Peng Chen, Matthias Weidemüller. 2018-04-04. Laser frequency stabilization using a commercial wavelength meter. https://doi.org/10.1063/1.5025537
Cite the original work for its findings. Save a collection to share your selection of sources.