Search arXivSearch

arXiv · 1804.05937

Enhancement of Throat Microphone Recordings Using Gaussian Mixture Model Probabilistic Estimator

Abstract

The throat microphone is a body-attached transducer that is worn against the neck. It captures the signals that are transmitted through the vocal folds, along with the buzz tone of the larynx. Due to its skin contact, it is more robust to the environmental noise compared to the acoustic microphone that picks up the vibrations through air pressure, and hence the all interventions. The throat speech is partly intelligible, but gives unnatural and croaky sound. This thesis tries to recover missing frequency bands of the throat speech and investigates envelope and excitation mapping problem with joint analysis of throat- and acoustic-microphone recordings. A new phone-dependent GMM-based spectral envelope mapping scheme, which performs the minimum mean square error (MMSE) estimation of the acoustic-microphone spectral envelope, has been proposed. In the source-filter decomposition framework, we observed that the spectral envelope difference of the excitation signals of throat- and acoustic-microphone recordings is an important source of the degradation in the throat-microphone voice quality. Thus, we also model spectral envelope difference of the excitation signals as a spectral tilt vector, and propose a new phone-dependent GMM-based spectral tilt mapping scheme to enhance throat excitation signal. Experimental evaluations are performed to compare the proposed mapping scheme using both objective and subjective evaluations. Objective evaluations are performed with the log-spectral distortion (LSD) and the wide-band perceptual evaluation of speech quality (PESQ) metrics. Subjective evaluations are performed with A/B pair comparison listening test. Both objective and subjective evaluations yield that the proposed phone-dependent mapping consistently improves performances over the state-of-the-art GMM estimators.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mehmet Ali Tugtekin Turan. 2018-04-13. Enhancement of Throat Microphone Recordings Using Gaussian Mixture Model Probabilistic Estimator. https://arxiv.org/abs/1804.05937

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Revisiting Lexicon Evaluation in Unsupervised Word Discovery

Building a lexicon from discovered word-like units is a central goal in zero-resource speech processing. But do our evaluations provide a trustworthy indication of lexicon quality? A common metric, normalized edit distance, averages the phoneme edit distances between discovered units in each cluster. We show that this metric has an inherent bias toward the quality of large clusters, inhibiting fair evaluation. Moreover, it ignores how well true classes are distributed across clusters. Based on established theory in clustering literature, we propose two metrics that address these shortcomings: a modified metric that weighs cluster size when assessing within-cluster consistency, and an inverse metric that assesses how true words are spread across clusters. Through experiments on synthetic and real-world lexicons, we demonstrate that combined, these metrics are: (1) more closely correlated with how similar a lexicon is to the ground-truth distribution, and (2) more robust to biases that skew lexicon evaluations.

eess.AS

AURA: Uncertainty-Routed Activation Editing for Acoustic Grounding in Speech Foundation Models

Attention encoder-decoder (AED) Speech Foundation Models achieve strong ASR performance but can generate acoustically unsupported text when inputs contain no speech, weak acoustic evidence, or unreliable transcription. We propose AURA: Activation-editing with Uncertainty-Routed Adaptation, an ultra-efficient representation-editing method that freezes the pretrained model and applies sparse scale-and-shift edits to decoder cross-attention heads. AURA dynamically routes edits using cross-attention uncertainty features that capture over-concentration, diffuse attention, and abrupt frame shifts. We evaluate AURA on four datasets spanning non-speech hallucination and speech grounding stressors, including imperfect-label child speech, imperfect-label adult speech, and disfluent speech. On non-speech audio, AURA reduces hallucination rate from 89.18% to 1.94% without prior hallucination-head identification. On imperfect-label corpora, AURA approaches LoRA WER while using roughly 500x fewer trainable parameters. Sensitivity analysis and qualitative cross-attention examples are consistent with AURA's uncertainty-routed editing behavior, supporting dynamic activation editing as a practical path for grounding AED speech models.

eess.AS

The design of an optomechanical microphone using a photonic waveguide interferometer

We present an optomechanical microphone based on a diaphragm-integrated photonic waveguide Mach-Zehnder interferometer. Acoustic pressure deforms the MEMS diaphragm, inducing strain in the sensing waveguide and changing its optical path length. We analytically evaluate the optical and mechanical transduction mechanisms and key figures of merit, including signal-to-noise ratio, dynamic range, acoustic overload pressure, and minimum detectable pressure. Two design cases are considered: a MEMS microphone and a measurement microphone. The results indicate competitive performance but no substantial overall advantage over state-of-the-art microphones in conventional applications. The architecture may nevertheless offer advantages for high-temperature and other harsh-environment sensing applications.

eess.AS