Search arXivSearch

arXiv · 1805.10021

The science case for POLLUX, a high-resolution UV spectropolarimeter onboard LUVOIR

Abstract

POLLUX is a high-resolution, UV spectropolarimeter proposed for the 15-meter primary mirror option of LUVOIR. The instrument Phase 0 study is supported by the French Space Agency (CNES) and performed by a consortium of European scientists. POLLUX has been designed to deliver high-resolution spectroscopy (R> 120,000) over a broad spectral range (90-390 nm). Its unique spectropolarimetric capabilities will open-up a vast new parameter space, in particular in the unexplored UV domain and in a regime where high-resolution observations with current facilities in the visible domain are severely photon starved. POLLUX will address a range of questions at the core of the LUVOIR Science portfolio. The combination of high resolution and broad coverage of the UV bandpass will resolve narrow UV emission and absorption lines originating in diffuse media, thus permitting the study of the baryon cycle over cosmic time: from galaxies forming stars out of interstellar gas and grains, and stars forming planets, to the various forms of feedback into the interstellar and intergalactic medium (ISM and IGM), and active galactic nuclei (AGN). UV circular and linear polarimetry will reveal the magnetic fields for a wide variety of objects for the first time, from AGN outflows to a diverse range of stars, stellar explosions (both supernovae and their remnants), the ISM and IGM. It will enable detection of polarized light reflected from exoplanets (or their circumplanetary material and moons), characterization of the magnetospheres of stars and planets (and their interactions), and measurements of the influence of magnetic fields at the (inter)galactic scale. In this paper, we outline the key science cases of POLLUX, together with its high-level technical requirements. The instrument design, its estimated performances, and the required technology development are presented in a separated paper.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jean-Claude Bouret, Coralie Neiner, Ana I. Gómez de Castro, Chris Evans, Boris Gaensicke, Steve Shore, Luca Fossati, Cécile Gry, Stéphane Charlot, Frédéric Marin, Pasquier Noterdaeme, Jean-Yves Chaufray. 2018-05-25. The science case for POLLUX, a high-resolution UV spectropolarimeter onboard LUVOIR. https://arxiv.org/abs/1805.10021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM