Search arXivSearch

arXiv · 1805.10127

Collapse of generalized Euler and surface quasi-geostrophic point-vortices

Abstract

Point vortex models are presented for the generalized Euler equations, which are characterized by a fractional Laplacian relation between the active scalar and the streamfunction. Special focus is given to the case of the surface quasi-geostrophic (SQG) equations, for which the existence of finite-time singularities is still a matter of debate. Point vortex trajectories are expressed using Nambu dynamics. The formulation is based on a noncanonical bracket and allows for a geometrical interpretation of trajectories as intersections of level sets of the Hamiltonian and Casimir. Within this setting, we focus on the collapse of solutions for the three point vortex model. In particular, we show that for SQG the collapse can be either self-similar or non-self-similar. Self-similarity occurs only when the Hamiltonian is zero, while non-self-similarity appears for non-zero values of the same. For both cases, collapse is allowed for any choice of circulations within a permitted interval. These results differ strikingly from the classical point vortex model, where collapse is self-similar for any value of the Hamiltonian, but the vortex circulations must satisfy a strict relationship. Results may also shed a light on the formation of singularities in the SQG partial differential equations, where the singularity is thought to be reached only in a self-similar way.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Gualtiero Badin, Anna M. Barry. 2018-08-15. Collapse of generalized Euler and surface quasi-geostrophic point-vortices. https://doi.org/10.1103/physreve.98.023110

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Surface Stokes drift from compact drifting wave buoys

Surface Stokes drift depends strongly on the energy and directions of short waves, which are incompletely resolved by routine wave observations. We derive surface Stokes drift vectors from wave measurements collected by compact drifting buoys during three deployments in the North-East Atlantic and the Alboran Sea. The calculation uses vertical-acceleration spectra and first directional Fourier moments, which describe the mean wave direction and directional concentration at each frequency; it accounts for the Doppler shift caused by buoy motion relative to the water and adds a calibrated high-frequency tail above an intrinsic frequency of 0.7 Hz. Across 13,139 records, the median estimated speed is 0.081 m/s at a median wind speed of 6.8 m/s. Over the measured band of 0.04-1 Hz, accounting for wave directions reduces the magnitude by a median 39% relative to the unidirectional assumption. The median ratio of the parameterised tail magnitude above 0.7 Hz to the total estimated magnitude is 0.37. Comparisons with WAVEWATCH III and Copernicus Marine MFWAM show strong covariation and similar wind-dependent differences from the buoy-derived estimates. On the station-matched sample from the two Atlantic deployments, WAVEWATCH III directional spectra indicate that these differences within the compared band arise mainly from spectral levels rather than from net directional reduction. The observations provide constraints for model evaluation; the contribution of the unresolved short waves remains sensitive to the assumed spectral tail and its directional spreading.

physics.ao-ph

Unreported large errors from two PAMGuard three-dimensional localizers of whale calls

Confidence intervals of location (CIL) of calling marine mammals, derived from time-differences-of-arrival (TDOA) between receivers, depend on errors of TDOAs, receiver location, clocks, sound speeds, and location method. When these errors are minuscule, simulations yield small errors of PAMGuard's 3D simplex localizer when click sounds of beaked and sperm whales originate in a 1000 x 1000 x 1000 $\mbox{m}^3$ region using five receivers having horizontal and vertical separations of 1000 m and 150 m respectively. Realistic uncertainties of sound speed up to $\pm 10$ m/s lead to errors up to $10^{14}$ m. With clocks maintained by atomic standards and common practice of correcting TDOA from synchronization measurements at the start and end of an experiment, errors of location are up to $10^{4}$ m. Errors up to $10^2$ and $10^3$ m are found when the receiver's locations are uncertain within 10 and 40 m respectively. Errors of PAMGuard's 3D hyperbolic localizer are almost independent of the above uncertainties, yielding errors of location up to about $10^4$ m even when simulated errors are minuscule. Causes of PAMGuard's 3D location errors are unknown. These algorithms are briefly compared to another method designed to yield a reliable CIL.

physics.ao-ph

Tropospheric Ozone Formation Potential and Related Design Considerations for Radiative Coolers

Recently, radiative coolers have been widely explored for reducing cooling loads or lowering temperatures in buildings, and at urban scales as a heat-mitigation measure. However, the potential impacts of radiative cooler deployment on the chemical composition of the atmosphere remain largely unexplored. A defining feature of recently-designed radiative coolers is their high ultraviolet (UV) reflectance, which is required for sub-ambient cooling under strong sunlight. Yet, wide adoption of such UV-reflective radiative coolers could substantially increase the UV actinic flux in the atmosphere above. This, in turn, may affect tropospheric ozone concentrations, particularly in urban atmospheres with high NOx concentrations. Here, as a case study, we use a 0-dimensional photochemical box model, constrained by field measurements of meteorological conditions and chemical concentrations in the urban environment of Houston, Texas, to explore the potential impact of the widespread use of UV-reflective radiative coolers on ozone concentrations. Our calculations show that complete deployment of radiative coolers may increase tropospheric ozone levels by as much as 30% during specific meteorological conditions in Houston. Informed by the wavelength-dependent modelling results, we propose specific designs, namely pigmented radiative coolers with different UV reflectances, and UV-absorptive visible-reemitting fluorescent radiative coolers, that could minimize negative ozone formation while retaining appreciable cooling performance. Our results motivate further study on the effects of widespread deployment of radiative cooling designs like superwhite roof paints on air quality, and materials that simultaneously minimize adverse photochemical impact and maximize cooling performance.

physics.ao-ph