Search arXivSearch

arXiv · 1806.10194

Characteristic Study and Development of Surface Resistivity Measuring Device for Resistive Plate Chamber Detector

Abstract

The India-based Neutrino Observatory (INO) is an approved multi-institutional experiment of India. It will use maximum 30,000 Resistive Plate Chamber (RPC) of size 2x2m as an active detector in which each will be sandwiched between two iron plates. Each RPC detectors will be made up of 3mm thick glass (or Bakelite) plates whose one surface will be coated with graphite paint to work as electrode. To achieve effective and uniform electric field, the coated graphite paint must have uniform distribution over the glass surface. Uniformity can be demonstrated by measuring the surface resistance of the coated graphite paint. However, manual measurement of 60,000 electrodes with the help of multimeter and the jig demands huge amount of person-hour with compromised accuracy, and therefore that requires the need and importance of the automatic scanning system. An advanced automatic scanning system (ASS) has been designed & developed to fulfill the required needs and overcome the shortcomings of the initially developed system. Measurement are sensitive to the contact pressure between the jig and RPC electrode's surface. In this paper, various parameters of the ASS have been precisely fixed. Obtained results are compared with the standard one and found satisfactory within error. It has been observed that for obtaining the correct and safe value of surface resistance, applied pressure value in terms of force should be in the range of 9-11 Newton.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A. Kumar, A. Pandey, N. Marimuthu, M. K. Singh, V. Singh, S. S. R. Inbanathan. 2018-06-21. Characteristic Study and Development of Surface Resistivity Measuring Device for Resistive Plate Chamber Detector. https://doi.org/10.1088/1748-0221%2F14%2F09%2Fc09044

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det