Detection of ultra-low concentration NO2 in complex environment using epitaxial graphene sensors

Abstract

We demonstrate proof-of-concept graphene sensors for environmental monitoring of ultra-low concentration NO2 in complex environments. Robust detection in a wide range of NO2 concentrations, 10-154 ppb, was achieved, highlighting the great potential for graphene-based NO2 sensors, with applications in environmental pollution monitoring, portable monitors, automotive and mobile sensors for a global real-time monitoring network. The measurements were performed in a complex environment, combining NO2/synthetic air/water vapour, traces of other contaminants and variable temperature in an attempt to fully replicate the environmental conditions of a working sensor. It is shown that the performance of the graphene-based sensor can be affected by co-adsorption of NO2 and water on the surface at low temperatures (<70 C). However, the sensitivity to NO2 increases significantly when the sensor operates at 150 C and the cross-selectivity to water, sulphur dioxide and carbon monoxide is minimized. Additionally, it is demonstrated that single-layer graphene exhibits two times higher carrier concentration response upon exposure to NO2 than bilayer graphene.

Explore related subjects

Keep this discovery

BibTeXRIS

Christos Melios, Vishal Panchal, Kieran Edmonds, Arseniy Lartsev, Rositsa Yakimova, Olga Kazakova. 2018-08-29. Detection of ultra-low concentration NO2 in complex environment using epitaxial graphene sensors. https://doi.org/10.1021/acssensors.8b00364

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det