Search arXivSearch

arXiv · 1810.10872

TCAD simulations of pixel sensors for the ATLAS ITk upgrade and performance of annealed planar pixel modules

Abstract

For the high luminosity phase of the Large Hadron Collider to start operation around 2026, a major upgrade of the ATLAS Inner Tracker (ITk) is in preparation. Thanks to their low power dissipation and high charge-collection efficiency after irradiation, thin planar pixel modules are the baseline option to instrument all, except for the innermost layer of the pixel detector. To optimise the sensor layout for a pixel cell size of $50\times50\,μm^2$, TCAD simulations are being performed. Charge-collection efficiency, electronic noise and electrical-field properties are investigated. A radiation-damage model is employed in TCAD simulations to estimate the performance before- and after irradiation. The impact of storage time at room temperature for the ITk pixel detector during maintenance periods are estimated using sensors irradiated up to a fluence of 5$\times10^{15}\,$n$_\text{eq}$/cm$^2$. Pixel sensors of $100-150\,μm$ thickness, interconnected to FE-I4 read-out chips with pixel dimensions of $50\times250\,μm^2$, are characterised using the testbeam facilities at the CERN-SPS and DESY. The charge-collection and hit efficiencies are compared before and after annealing at room temperature for up to one year.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Julien-Christopher Beyer, Alessandro La Rosa, Anna Macchiolo, Richard Nisius, Natascha Savic, Reem Taibah. 2018-10-24. TCAD simulations of pixel sensors for the ATLAS ITk upgrade and performance of annealed planar pixel modules. https://doi.org/10.1088/1748-0221%2F13%2F11%2Fc11001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det