Search arXivSearch

arXiv · 1810.11770

Towards Human Pulse Rate Estimation from Face Video: Automatic Component Selection and Comparison of Blind Source Separation Methods

Abstract

Human heartbeat can be measured using several different ways appropriately based on the patient condition which includes contact base such as measured by using instruments and non-contact base such as computer vision assisted techniques. Non-contact based approached are getting popular due to those techniques are capable of mitigating some of the limitations of contact-based techniques especially in clinical section. However, existing vision guided approaches are not able to prove high accurate result due to various reason such as the property of camera, illumination changes, skin tones in face image, etc. We propose a technique that uses video as an input and returns pulse rate in output. Initially, key point detection is carried out on two facial subregions: forehead and nose-mouth. After removing unstable features, the temporal filtering is applied to isolate frequencies of interest. Then four component analysis methods are employed in order to distinguish the cardiovascular pulse signal from extraneous noise caused by respiration, vestibular activity and other changes in facial expression. Afterwards, proposed peak detection technique is applied for each component which extracted from one of the four different component selection algorithms. This will enable to locate the positions of peaks in each component. Proposed automatic components selection technique is employed in order to select an optimal component which will be used to calculate the heartbeat. Finally, we conclude with a comparison of four component analysis methods (PCA, FastICA, JADE, SHIBBS), processing face video datasets of fifteen volunteers with verification by an ECG/EKG Workstation as a ground truth.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vladislav Ostankovich, Geesara Prathap, Ilya Afanasyev. 2018-10-28. Towards Human Pulse Rate Estimation from Face Video: Automatic Component Selection and Comparison of Blind Source Separation Methods. https://doi.org/10.1109/is.2018.8710532

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

SAMReg: SAM-enabled Image Registration with ROI-based Correspondence

This paper describes a new spatial correspondence representation based on paired regions-of-interest (ROIs), for medical image registration. The distinct properties of the proposed ROI-based correspondence are discussed, in the context of potential benefits in clinical applications following image registration, compared with alternative correspondence-representing approaches, such as those based on sampled displacements and spatial transformation functions. These benefits include a clear connection between learning-based image registration and segmentation, which in turn motivates two cases of image registration approaches using (pre-)trained segmentation networks. Based on the segment anything model (SAM), a vision foundation model for segmentation, we develop a new registration algorithm SAMReg, which does not require any training (or training data), gradient-based fine-tuning or prompt engineering. The proposed SAMReg models are evaluated across five real-world applications, including intra-subject registration tasks with cardiac MR and lung CT, challenging inter-subject registration scenarios with prostate MR and retinal imaging, and an additional evaluation with a non-clinical example with aerial image registration. The proposed methods outperform both intensity-based iterative algorithms and DDF-predicting learning-based networks across tested metrics including Dice and target registration errors on anatomical structures, and further demonstrates competitive performance compared to weakly-supervised registration approaches that rely on fully-segmented training data. Open source code and examples are available at: https://github.com/sqhuang0103/SAMReg.git.

cs.CV

Q-SiT: Teaching LMMs for Image Quality Scoring and Interpreting

Image quality scoring and interpreting are two fundamental components of Image Quality Assessment (IQA). The former quantifies image quality, while the latter enables descriptive question answering about image quality. Traditionally, these two tasks have been addressed independently. However, image-quality-specific psychophysical studies suggest that these two tasks are conceptually interconnected: interpreting explicitly represents perceived quality attributes whereas scoring summarizes such evidence into an overall quality judgment. Thus, unifying these capabilities within a single model is both intuitive and logically coherent. In this paper, we propose Q-SiT (Quality Scoring and Interpreting joint Teaching), a unified framework that enables large multimodal models (LMMs) to learn both image quality scoring and interpreting simultaneously. We achieve this by transforming conventional IQA datasets into learnable question-answering datasets and incorporating human-annotated quality interpreting data for training. Furthermore, we introduce an efficient scoring \& interpreting balance strategy, which first determines the optimal data mix ratio on lightweight LMMs and then maps this ratio to primary LMMs for fine-tuning adjustment. This strategy not only mitigates task interference and enhances cross-task knowledge transfer but also significantly reduces computational costs compared to direct optimization on full-scale LMMs. With this joint learning framework and corresponding training strategy, we develop Q-SiT, the first model capable of simultaneously performing image quality scoring and interpreting tasks, along with its lightweight variant, Q-SiT-mini. Experimental results demonstrate that Q-SiT achieves strong performance in both tasks with superior generalization IQA abilities, while Q-SiT-mini significantly reduces computational overhead while maintaining competitive performance.

cs.CV

Preserving Guidance in Cost-Volume Retrieval under Extreme LiDAR Sparsity in Iterative Stereo

While accurate LiDAR depth has been shown to improve stereo matching, high-end LiDAR remains costly and difficult to deploy at scale, motivating guidance from sparse LiDAR measurements. In this paper, we revisit how extremely sparse LiDAR can guide iterative stereo by examining its cost-volume retrieval mechanism. Our analysis shows that LiDAR guidance degrades sharply when only a few hundred points are available, and we provide a signal-processing explanation for why iterative stereo fails to fully exploit such sparse input. This insight leads to a simple yet highly effective remedy: pre-filling the initial disparity map so that cost-volume retrieval becomes more reliable under extremely sparse LiDAR. We find that pre-filling is also effective when injecting LiDAR depth into image features via early fusion, but for a fundamentally different reason, necessitating a distinct pre-filling approach. Combining both forms of guidance, our proposed Guided RAFT-Stereo (GRAFT-Stereo) achieves substantial improvements over existing LiDAR-guided stereo methods across multiple datasets.

cs.CV