Abstract

We present proof-of-operation for a new method of electron thermometry using microwave impedance of a hafnium micro-absorber. The new method leads to an ultimate THz-range detector suitable for microwave readout and frequency division multiplexing. The sensing part of the device is a hot-electron-gas absorber responding to the incident radiation by variation of its impedance measured at probing frequency about 1.5 GHz. The absorber is a microbridge made from hafnium (Tc = 375 mK, RN = 30 Ohm) sized 2.5 um by 2.5 um by 50 nm and integrated with a planar 600-700 GHz antenna placed near the open end of a quarter-wave CPW resonator (Q-factor about 10^4). All elements of the circuit, except the microbridge, are made from 100-nm thick Nb, including the resonator, which is weakly coupled to a throughput line. The device was tested at 50-350 mK smoothly responding with its transmission coefficient S21 to applied microwave power at the resonance frequency. We have found that the power absorbed by the bridge fits to the model of hot electron gas, P=k(Te^n-Tph^n) (n = 5...6). The idle NEP down to about 10^-18 W/Hz^(-1/2) and the corresponding cross-over temperature for photon background about 5 K are estimated from the measured data. The saturation power of about 1 pW and possibility of moderate gain are anticipated for a practicable device operating at temperature 200 mK. Since the optimum readout frequency is found exactly at the resonance, the detector is insensitive to most phase instabilities at the probing frequency.

Explore related subjects

Keep this discovery

BibTeXRIS

A. V. Merenkov, V. I. Chichkov, A. B. Ermakov, A. V. Ustinov, S. V. Shitov. 2018-12-11. Microwave impedance readout of a hafnium microbridge detector. https://arxiv.org/abs/1812.04686

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det