Search arXivSearch

arXiv · 1901.01463

Probing 10 μK stability and residual drifts in the cross-polarized dual-mode stabilization of single-crystal ultrahigh-Q optical resonators

Abstract

The thermal stability of monolithic optical microresonators is essential for many mesoscopic photonic applications such as ultrastable laser oscillators, photonic microwave clocks, and precision navigation and sensing. Their fundamental performance is largely bounded by thermal instability. Sensitive thermal monitoring can be achieved by utilizing cross-polarized dual-mode beat frequency metrology, determined by the polarization-dependent thermorefractivity of a single-crystal microresonator, wherein the heterodyne radio-frequency beat pins down the optical mode volume temperature for precision stabilization. Here, we investigate the correlation between the dual-mode beat frequency and the resonator temperature with time and the associated spectral noise of the dual-mode beat frequency in a single-crystal ultrahigh-Q MgF2 resonator to illustrate that dual-mode frequency metrology can potentially be utilized for resonator temperature stabilization reaching the fundamental thermal noise limit in a realistic system. We show a resonator long-term temperature stability of 8.53 μK after stabilization and unveil various sources that hinder the stability from reaching sub-μK in the current system, an important step towards compact precision navigation, sensing and frequency reference architectures.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jinkang Lim, Wei Liang, Anatoliy A. Savchenkov, Andrey B. Matsko, Lute Maleki, Chee Wei Wong. 2019-01-05. Probing 10 μK stability and residual drifts in the cross-polarized dual-mode stabilization of single-crystal ultrahigh-Q optical resonators. https://doi.org/10.1038/s41377-018-0109-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade

The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for sterile neutrinos with keV masses. This entails performing precision electron spectroscopy with over one thousand silicon drift detector pixels, each responsible for recording incident electron rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges through a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement.

physics.ins-det

True Alternating Current Scanning Tunneling Microscope (ACSTM): tunneling on insulators

Scanning Tunneling Microscopy (STM) has revolutionized our atomic scale understanding of surfaces and accelerated progress in nanotechnology. This technique, however, is restricted to metal or semiconducting samples, as it requires a tiny current to stabilize the tip-sample distance with atomic scale precision. We developed a new imaging and feedback method that relies on true alternating current (AC) without any direct current (DC) component. This technique does not only enable the imaging on non-conducting surfaces with atomic step resolution, like (thin) glass and oxides, it provides also access to high-frequency electronic signal coming from the sample. We demonstrate that it is possible to measure on 25nm thick silicon oxide with 10 MHz tunneling current.

physics.ins-det

Charged-particle topology reconstruction with an in-liquid SiPM array

Liquid scintillator detectors instrumented with photosensors inside the scintillation volume preserve local optical information that is largely lost in conventional boundary-readout geometries. We demonstrate that this information is sufficient for charged-particle topology reconstruction using a sparse three-dimensional lattice of silicon photomultipliers. After validating the Geant4 detector response against measured photon-count distributions, a simulation-trained, time-informed convolutional neural network reconstructs the entry and exit points of through-going muons with median residuals of 1.91~cm and 2.39~cm, respectively. The reconstructed endpoints are geometrically consistent with acceptance regions defined by external trigger counters in cosmic-ray muon data. The same framework also reconstructs the production vertices of simulated positron starting-track events with a median residual of about 4.5~cm. These results establish the feasibility of topology-sensitive reconstruction using sparse in-liquid photosensor arrays in homogeneous liquid scintillator detectors.

physics.ins-det