Search arXivSearch

arXiv · 1902.02446

Gallium Nitride Photodetector Measurements of UV Emission from a Gaseous CH4/O2 Hybrid Rocket Igniter Plume

Abstract

Owing to its wide (3.4 eV) and direct-tunable band gap, gallium nitride (GaN) is an excellent material platform for UV photodetectors. GaN is also stable in radiation-rich and high-temperature environments, which makes photodetectors fabricated using this material useful for in-situ flame detection and combustion monitoring. In this paper, we use a GaN photodetector to measure ultraviolet (UV) emissions from a hybrid rocket motor igniter plume. The normalized photocurrent-to-dark current ratio (NPDR) is a performance metric which simultaneously captures the two desired characteristics of high responsivity and low dark current. The NPDR of our device is record-high with a value of 6 x 10$^{14}$ W$^{-1}$ and the UV-to-visible rejection ratio is 4 x 10$^6$. The photodetector shows operation at high temperatures (up to 250°C), with the NPDR still remaining above 10$^9$ W$^{-1}$ and the peak wavelength shifting from 362 nm to 375 nm. The photodetector was placed at three radial distances (3", 5.5", and 7") from the base of the igniter plume and the oxidizer-to-fuel ratio (O2/CH4) was varied. The data demonstrates a clear trend of increasing current (and thus intensity of plume emission) with increasing fuel concentration and decreasing separation between the photodetector and the plume. By treating the plume as a black body, and calculating a radiative configuration factor corresponding to the geometry of the plume and the detector, we calculated average plume temperatures at each of the three oxidizer-to-fuel ratios. The estimated plume temperatures were between 850 and 950 K for all three combustion conditions. The temperature is roughly invariant for a fixed fuel concentration for the three tested distances. These data demonstrate the functionality of GaN as a material platform for use in harsh environment flame monitoring.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hannah S. Alpert, Ananth Saran Yalamarthy, Peter F. Satterthwaite, Elizabeth Jens, Jason Rabinovitch, Noah Scandrette, A. K. M. Newaz, Ashley C. Karp, Debbie G. Senesky. 2019-02-07. Gallium Nitride Photodetector Measurements of UV Emission from a Gaseous CH4/O2 Hybrid Rocket Igniter Plume. https://arxiv.org/abs/1902.02446

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

TCAD + Allpi$\text{x}^2$ Simulation study of MALTA2, a Depleted Monolithic Active Pixel Sensor for future tracking

In this work, a hybrid simulation framework combining TCAD and Allpi$\text{x}^2$ is presented to investigate the sensor properties of MALTA2, a depleted monolithic active pixel sensor designed for future tracking. The study starts from 3D modeling and transient simulations in TCAD, with generic doping profiles and simple well structures. The resulting doping profiles and electric field are extracted and fed into Allpi$\text{x}^2$ for high-statistics Monte Carlo simulations in both DUT-only and full-telescope mode. Simulations reveal a strong dependence of sensor performance, specifically the detection efficiency and cluster size, on the doping concentration of the N-type blanket at the sensor surface. The doping concentration is then optimized by comparing simulations with measurement data. The active depth of the depleted region of the MALTA2 sensor is estimated in both simulations and measurements using a grazing angle method, in which the sensor is positioned at various inclinations relative to the beam, covering angles from 0 to 60 degrees. Excellent agreement on active depth is obtained with the optimal doping concentration, showing a deviation of 2\% from the measured value at a threshold of 450\,$\text{e}^-$. Consequently, the framework offers a generic toolkit for sensor studies without requiring proprietary information.

physics.ins-det

A compact fibre-coupled active beamstop for fast time-resolved monitoring of synchrotron X-ray beams

We have developed a compact fibre-coupled active beamstop for simultaneous interception and time-resolved monitoring of the direct X-ray beam in synchrotron diffraction experiments. The complete beamstop tip has a maximum transverse dimension of 1 mm and incorporates a 700 $μ$m-wide Ce:YAG scintillator. The scintillator converts the intercepted X-rays into visible light, which is transported through a multimode optical fibre to a silicon photodiode at the bottom of the blade that is connected to a dedicated fast amplifier electronics. Tests with a pulsed laser yielded a system decay time of 69.4 ns, consistent with reported luminescence decay times for Ce:YAG. Measurements at the P14.EH2 end station of PETRA III demonstrated the detection of individual bunch signals separated by 192 ns in the 40-bunch operating mode. The active beamstop also provided an in-situ timing signal for synchronising an experimental sequence with the approximately 190 $μ$s transmission window of a mechanical X-ray chopper. The device therefore combines a compact obstruction of the direct beam with fast monitoring of X-ray timing and flux during diffraction data acquisition.

physics.ins-det

Charge-Carrier transport simulations in diamond detectors with electric-field-dependent mobility and charge-collection-distance-based trapping

Diamond detectors are attractive for operation in harsh radiation environments because they combine radiation tolerance, fast signal formation, and low leakage current. Realistic detector-response simulations require an accurate description of charge-carrier mobility and trapping, which determine both signal amplitude and timing. In this work, we extend \allpix{}, a modular end-to-end detector simulation framework, with diamond-specific transport models. The implementation includes field-dependent mobility parameterizations for electrons and holes and an effective trapping model based on the charge collection distance (CCD), providing a detector-level interface to material quality and radiation-damage measurements. The mobility description is validated in the negligible-trapping limit using single-crystalline CVD diamond by comparing simulated drift velocities and transient-current signals with published reference data. For polycrystalline CVD diamond, the CCD-based trapping model is evaluated using experimentally measured CCD values and compared with laboratory transient-current-technique waveforms. The simulations reproduce the measured drift-velocity behavior in scCVD and the reduced charge collection and degraded transient response observed in pcCVD. The presented implementation enables detector-level studies of charge collection, pulse formation, and timing performance in diamond sensors using experimentally accessible transport and trapping parameters, and provides a practical framework for simulation-driven detector development and radiation-damage studies.

physics.ins-det