Application of deconvolution to recover frequency-domain multiplexed detector pulses

Abstract

Multiplexing of radiation detectors reduces the number of readout channels, which in turn reduces the number of digitizer input channels for data acquisition. We recently demonstrated frequency domain multiplexing (FDM) of pulse mode radiation detectors using a resonator that converts the detector signal into a damped sinusoid by convolution. The detectors were given unique "tags" by the oscillation frequency of each resonator. The charge collected and the time-of-arrival of the detector pulse were estimated from the corresponding resonator output in the frequency domain. In this paper, we demonstrate a new method to recover the detector pulse from the damped sinusoidal output by deconvolution. Deconvolution converts the frequency-encoded detector signal back to the original detector pulse. We have developed a new prototype FDM system to multiplex organic scintillators based on convolution and deconvolution. Using the new prototype, the charge collected under the anode pulse can be estimated from the recovered pulse with an uncertainty of about 4.4 keVee (keV electron equivalent). The time-of-arrival can be estimated from the recovered pulse with an uncertainty of about 102 ps. We also used a CeBr3 inorganic scintillator to measure the Cs-137 gamma spectrum using the recovered pulses and found a standard deviation of 13.8 keV at 662 keV compared to a standard deviation of 13.5 keV when the original pulses were used. Coincidence measurements with Na-22 using the deconvolved pulses resulted in a timing uncertainty of 617 ps compared to an uncertainty of 603 ps using the original pulses. Pulse shape discrimination was also performed using Cf-252 source and EJ-309 organic scintillator pulses recovered by deconvolution. A figure of merit value of 1.08 was observed when the recovered pulses were used compared to 1.2 for the original pulses.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Mishra, J. Mattingly, R. M. Kolbas. 2019-02-22. Application of deconvolution to recover frequency-domain multiplexed detector pulses. https://doi.org/10.1016/j.nima.2019.03.043

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Multi-Carrier Rydberg Atomic Quantum Receivers with Enhanced Bandwidth Feature for Communication and Sensing

Rydberg atomic quantum receivers (RAQRs) have attracted significant attention in recent years due to their ultra-high sensitivity. Although capable of precisely detecting the amplitude and phase of weak signals, conventional RAQRs face inherent limitations in accurately receiving wideband RF signals, due to the discrete nature of atomic energy levels and their intrinsic instantaneous bandwidth constraints. These limitations hinder their direct application to multi-carrier communication and sensing. To address this issue, this paper proposes a multi-carrier Rydberg atomic quantum receiver (MC-RAQR) structure with five energy levels. We derive the amplitude and phase of the MC-RAQR and extract the baseband electrical signal for signal processing. In terms of multi-carrier communication and sensing, we analyze the channel capacity and accuracy of angle of arrival (AoA) and distance parameters, respectively. Numerical results validate our proposed model, showing that the MC-RAQR can achieve up to a bandwidth of 11.7 MHz, which is 17-fold larger than the conventional RAQRs. As a result, the channel capacity and the resolution for multi-target sensing are improved significantly. Specifically, the channel capacity of MC-RAQR is 110-fold and 2.8-fold larger than the classical RF receivers and RAQRs, respectively. For sensing performance, the RMSE of AoA estimation for MC-RAQR exhibits 7.6-fold reduction, compared with the conventional RAQRs. Furthermore, the RMSE of distance estimation is $634$-fold smaller than that of the root-CRB of classical RF receivers, showing the superior performance of the MC-RAQR. This demonstrates its compatibility with waveforms such as orthogonal frequency-division multiplexing (OFDM) and its significant advantages for multi-carrier signal reception.

eess.SP

Channel Estimation in MIMO Systems Aided by Microwave Linear Analog Computers (MiLACs)

Microwave linear analog computers (MiLACs) have recently emerged as a promising solution for future gigantic multiple-input multiple-output (MIMO) systems, enabling beamforming with greatly reduced hardware and computational cost. However, channel estimation for MiLAC-aided systems remains an open problem. Conventional least squares (LS) and minimum mean square error (MMSE) estimation rely on intensive digital computation, which undermines the computational advantage offered by MiLACs. In this letter, we propose efficient LS and MMSE channel estimation schemes for MiLAC-aided MIMO systems. By designing the training precoder and combiner implemented by lossless and reciprocal MiLACs, the proposed schemes perform LS and MMSE estimation in the analog domain, leaving only simple digital scaling. They achieve identical estimation performance to their digital counterparts while significantly reducing computational complexity. Numerical results verify the effectiveness of the proposed schemes.

eess.SP

Joint Subcarrier Phase Recovery for Nonlinearity Mitigation

We propose a low-complexity phase recovery scheme that simultaneously mitigates laser phase noise and fiber nonlinearity across several subcarriers. In a long single-span link with Raman amplification, the scheme achieves 0.9 dB gain with 99 real multiplications per complex symbol.

eess.SP