Search arXivSearch

arXiv · 1902.10891

A distortion solution for the Bok telescope with four CCD chips

Abstract

The Beijing-Arizona Sky Survey (BASS) is an imaging survey and uses the 2.3 m Bok telescope at Kitt Peak. In order to tap the astrometric potential of the Bok telescope and improve the astrometry of BASS, a distortion solution for the Bok telescope is made. In the past, we used a single lookup table to correct all the positional errors. However, this method can not be applied to the reduction of the observation for the Bok telescope where four CCD chips are equipped with. Then quite different from our previous method, two third-order polynomials were used to fit the lookup table. By using the polynomial Geometric Distortion (called GD hereafter) correction the astrometry of BASS is improved greatly. Moreover, an additional lookup table correction is found to be more effective to obtain a final GD. The results show that the positional measurement precision of the appropriate bright stars is estimated at about 20 mas and even better in each direction. Besides, the relative positions of the chips are measured. The change of the inter-chip gaps in horizontal or vertical is no more than 5 pixel between 2016 and 2017 and the change of the roll angle is no more than 0.1 degree.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N. Wang, Q. Y. Peng, X. Zhou, X. Y. Peng, H. W. Peng. 2019-02-28. A distortion solution for the Bok telescope with four CCD chips. https://doi.org/10.1093/mnras%2Fstz459

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Performance characterization of a new Structural and Thermal Architecture for a future spaceborne Closed-Cycle Dilution Refrigerator

A Structural and Thermal Model (STM) has been developed to support the new spaceborne Closed-Cycle Dilution Refrigerator (CCDR), which aims to provide continuous cooling at 100~mK for long-duration astrophysical missions. The STM is based on a hexapod architecture that ensures both thermal decoupling and mechanical robustness during launch. In this paper, we present the characterization of its thermal and mechanical performances. A dedicated experimental setup was used to investigate the thermal behavior of the STM across a broad temperature range. The study reveals limitations of the collar design, with incomplete power interception from thermal boundary resistances and vibration test failure traced to defective strut gluing. These results guide the next STM iteration with optimized collar and strut assembly for reliable CCDR operation in space.

astro-ph.IM

The Simons Observatory: Development of a Pipeline to Detect Rapid Transients in Time-Ordered Data

We introduce a method for detecting astrophysical transients evolving on timescales of milliseconds to minutes using cosmic microwave background (CMB) survey telescopes. While previous transient searches in CMB data operate in map space, our pipeline directly processes the raw time-ordered data, enabling sensitivity to fast, dynamic signals. We integrate our detection approach into the Simons Observatory time-domain pipeline and assess the performance by injecting symmetric, stellar flare-like light curves into simulated observations. For events flaring with a timescale of 0.5 s, the pipeline detects $\gtrsim90$ % of events at flux densities of 800, 1150, 1650, and 4250\,mJy when measured in the 93, 145, 225, and 280 GHz bands respectively. At a fixed peak flux density, the pipeline more readily detects longer flares. The limiting flux density for 90 % completeness is four times lower for a $\ge5$ s flare than for a 0.5 s flare, while the flux density limits for $\gtrsim50$ % detection efficiency are comparable to the rms noise of the time-ordered data. We are able to determine the position of detected events in each observing band, with a positional uncertainty at the detection threshold comparable to the telescope resolution at that band. These results demonstrate the readiness of this pipeline for incorporation into upcoming Simons Observatory data analyses.

astro-ph.IM

Thermal conductivity of various CFRPs from 100 mK to 20 K

Carbon-fiber-reinforced polymers (CFRPs) are some of the most useful materials for building spacecraft and aerospace tools. They are especially valuable for systems that work at extremely cold (cryogenic) temperatures because they are strong, lightweight, and don't transfer heat easily. In this study, researchers measured how well heat moves through several different types of carbon fiber samples, specifically T300, T700, HS40, M55J, and IMA, at different fiber layouts and densities. These measurements were taken at ultra-cold temperatures ranging from 100 mK to 20 K. The team used a newly developed analysis method to calculate the thermal conductivity for each sample. Finally, they shared how each material behaved at different temperatures and compared their findings to previous research.

astro-ph.IM