Search arXivSearch

arXiv · 1903.09451

Mitigation of Through-Wall Distortions of Frontal Radar Images using Denoising Autoencoders

Abstract

Radar images of humans and other concealed objects are considerably distorted by attenuation, refraction and multipath clutter in indoor through-wall environments. While several methods have been proposed for removing target independent static and dynamic clutter, there still remain considerable challenges in mitigating target dependent clutter especially when the knowledge of the exact propagation characteristics or analytical framework is unavailable. In this work we focus on mitigating wall effects using a machine learning based solution -- denoising autoencoders -- that does not require prior information of the wall parameters or room geometry. Instead, the method relies on the availability of a large volume of training radar images gathered in through-wall conditions and the corresponding clean images captured in line-of-sight conditions. During the training phase, the autoencoder learns how to denoise the corrupted through-wall images in order to resemble the free space images. We have validated the performance of the proposed solution for both static and dynamic human subjects. The frontal radar images of static targets are obtained by processing wideband planar array measurement data with two-dimensional array and range processing. The frontal radar images of dynamic targets are simulated using narrowband planar array data processed with two-dimensional array and Doppler processing. In both simulation and measurement processes, we incorporate considerable diversity in the target and propagation conditions. Our experimental results, from both simulation and measurement data, show that the denoised images are considerably more similar to the free-space images when compared to the original through-wall images.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shelly Vishwakarma, Shobha Sundar Ram. 2019-03-22. Mitigation of Through-Wall Distortions of Frontal Radar Images using Denoising Autoencoders. https://doi.org/10.1109/tgrs.2020.2978440

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Subspace Learning with Interval-Censored Likelihoods for Dequantizing Percept PC LFP Snapshots

Implanted neurostimulators that sense local field potentials now enable chronic electrophysiology based biomarker tracking in patients at home. The Medtronic Percept PC, the only commercially available sensing-enabled deep brain stimulation (DBS) device, stores spectral amplitudes as 16-bit integers at approximately 0.1 $μ$V per bit (quantum $q \approx 0.11$ $μ$Vp). At frequencies where the true amplitude spans only a few quantization levels, consecutive bins round to the same stored value. Standard spectral parameterization (FOOOF, fitting oscillations and one over f), which separates periodic peaks from the aperiodic 1/f activity, treats every value as exact and fits oscillatory peaks to these plateaus. Because these spectra feed clinical biomarker pipelines and spectral foundation models for symptom decoding, spurious peaks can corrupt downstream inference. Across 9,438 spectra from 14 hemispheres in 7 subcallosal cingulate DBS patients, 20.6% of peaks detected at [2, 45] Hz have no match in ground truth synthesized by quantizing clean in-clinic BrainSense recordings, while aggregate beta band power and the aperiodic exponent are preserved. We formalize dequantization as interval-censored subspace estimation and compare five classes of correction methods. Quantized probabilistic PCA is the only tested method that reduces the spurious rate (20.6% to 18.3%) while preserving true peak detection and keeping noise floor RMSE below $q/\sqrt{12}$.

eess.SP

TiamiTwin: A Digital Twin for Bistatic ISAC Drone Sensing, Validated Against Measurements

Monitoring lower airspace over critical infrastructure using cellular signals of opportunity is highly practical because transmitters are pre-deployed, licensed, and continuously active. Digital twins can evaluate the feasibility of such integrated sensing and communication (ISAC) architectures, but their predictive accuracy must be validated against real-world data. This paper reports validation results for TiamiTwin, a digital twin developed for bistatic ISAC drone sensing, using empirical measurements from an operational 5G deployment featuring a commercial band n41 gNB and a receiver separated by 572.8 m over a non-line-of-sight (NLOS) channel. TiamiTwin incorporates three parallel channel representations evaluated on a 240-subcarrier grid: the 3GPP TR 38.901 (Release 19) bistatic ISAC model, a ray-traced site model, and the captured field measurements. Empirical results demonstrate that both statistical and ray-tracing models under-predict the measured root-mean-square (RMS) delay spread by approximately a factor of three. Furthermore, target reflections sit 68 dB below static clutter in power, making target detection entirely dependent on Doppler separation to isolate the drone from zero-Doppler background returns. Despite this severe clutter environment, the target remains separable along 88% of the flight path in the delay, Doppler, or joint delay-Doppler domains.

eess.SP

Extracting Physiological Numeric Values from French Pediatric ICU Notes: A Multi-Objective Representation Learning Approach

Numeric values in clinical narratives, such as heart rate, oxygen saturation, and pressure gradients, carry diagnostic meaning that Transformer models trained on generic text do not capture. Objective: We categorize numerical values in French pediatric intensive care unit (PICU) notes into eight physiological categories using CamemBERT-bio, under two constraints that make large-scale LLMs impractical: only 1,072 real, annotated clinical samples are available for this rare, single-site condition, and training must run on GPUs shared concurrently with other hospital workloads rather than a dedicated cluster. Methods: We compare fine-tuning CamemBERT-bio with Label Embedding for Self-Attention (LESA) against combining LESA with Xval, a magnitude-aware number embedding, under a multi-objective training loss. Results: Standard fine-tuning did not improve F1 score, but CamemBERT-bio + LESA raised it by over 13%, and adding Xval matched this gain while approaching GPT-4's performance. Conclusion: LESA and Xval let a compact encoder achieve reliable physiological value extraction under limited real data and shared hospital compute, offering a practical alternative to large-scale LLMs. Significance: Under limited-data and shared-compute constraints, this compact BERT-based language model remains effective without the resource trade-offs of trillion-parameter LLMs.

eess.SP