Search arXivSearch

arXiv · 1907.06000

Detection of Influenza A Virus Nucleoprotein Through the Self-Assembly of Nanoparticles in Magnetic Particle Spectroscopy-Based Bioassays: A Method for Rapid, Sensitive, and Wash-free Magnetic Immunoassays

Abstract

Magnetic nanoparticles (MNPs) with proper surface functionalization have been extensively applied as labels for magnetic immunoassays, carriers for controlled drug/gene delivery, tracers and contrasts for magnetic imaging, etc. Here, we introduce a new biosensing scheme based on magnetic particle spectroscopy (MPS) and the self-assembly of MNPs to quantitatively detect H1N1 nucleoprotein molecules. MPS monitors the harmonics of oscillating MNPs as a metric for the freedom of rotational motion, thus indicating the bound states of MNPs. These harmonics can be readily collected from nanogram quantities of iron oxide nanoparticles within 10 s. H1N1 nucleoprotein molecule hosts multiple different epitopes that forms binding sites for many IgG polyclonal antibodies. Anchoring IgG polyclonal antibodies onto MNPs triggers the cross-linking between MNPs and H1N1 nucleoprotein molecules, thereby forming MNP self-assemblies. Using MPS and the self-assembly of MNPs, we achieved the sensitivity of 44 nM (442 pmole) for detecting H1N1 nucleoprotein. In addition, the morphologies and the hydrodynamic sizes of the MNP self-assemblies are characterized to verify the MPS results. Different MNP self-assembly models such as classical cluster, open ring tetramer, chain model as well as multimers (from dimer to pentamer) are proposed in this paper. Herein, we claim the feasibility of using MPS and the self-assembly of MNPs as a new biosensing scheme for detecting ultralow concentrations of target biomolecules, which can be employed as rapid, sensitive, and wash-free magnetic immunoassays.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kai Wu, Jinming Liu, Renata Saha, Diqing Su, Venkatramana D. Krishna, Maxim C-J Cheeran, Jian-Ping Wang. 2019-07-13. Detection of Influenza A Virus Nucleoprotein Through the Self-Assembly of Nanoparticles in Magnetic Particle Spectroscopy-Based Bioassays: A Method for Rapid, Sensitive, and Wash-free Magnetic Immunoassays. https://arxiv.org/abs/1907.06000

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Janus Dipoles: Fundamentals, Realizations, and Emerging Applications

The Janus dipole - featuring orthogonally oriented electric and magnetic dipoles with a 90-degree phase difference - has emerged as a powerful paradigm for wave manipulation. Unlike traditional Huygens dipoles used for directional control, this unique configuration exhibits strongly asymmetric, face-selective near-field behavior while maintaining a quasi-isotropic far-field radiation pattern. These remarkable properties make the Janus dipole an essential platform for directional wave shaping, with wide-ranging applications in on-chip photonics, quantum interactions, and wireless power transfer. This review systematically traces the rapid development of the Janus dipole from its foundational theoretical inception to its diverse implementation platforms across optical, microwave, and acoustic frequencies. In this paper, we explore the governing principles, classify realization strategies into passive Janus dipoles, active Janus dipoles, and advanced near-field coupling control, and highlight emerging frontiers. By bridging foundational electrodynamics with advanced device engineering, this paper serves as an essential reference and roadmap for researchers designing next-generation, highly integrated, and compact wave-manipulation systems.

physics.app-ph

Pendellösung length-scale neutron and X-ray interferometry

Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 $μ$m and 350 $μ$m, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.

physics.app-ph

A State-Space Framework for trivial and Topological Metamaterial Stochastic Analysis

Topological phononic crystals and elastic metamaterials support edge states defined by global topological invariants, offering a route toward vibration-control and wave-guiding devices that remain functional in the presence of defects. However, manufacturing-induced spatial variability can perturb these invariants and compromise their robustness, making its quantification essential during design. In this work, we first demonstrate that a previously proposed linear time-varying (LTV) formulation is mathematically equivalent to the spectral element method based on transfer matrices for elementary rod, Saint-Venant shaft, and Euler-Bernoulli beam theories. The deterministic formulation is then extended to stochastic analyses through a stochastic linear time-varying (SLTV) framework. The proposed methodology combines Monte Carlo simulations with stochastic Fourier series and an analytical Karhunen--Loève expansion, providing closed-form stochastic fields and their derivatives required by the LTV formulation. The SLTV approach enables the computation of stochastic dispersion diagrams and forced responses of one-dimensional waveguides with arbitrarily varying geometry and mechanical properties. Because the LTV-based transition matrix isolates individual wavemodes without requiring the mode tracking needed by conventional eigenproblem-based formulations, the framework is particularly suited for evaluating topological invariants, specifically the Zak phase, and assessing the robustness of topological bands under spatial variability. Numerical results for rods, shafts, and Euler-Bernoulli beams demonstrate the applicability of the proposed framework as a unified methodology for deterministic and stochastic analyses of trivial and topological periodic waveguides under continuous spatial uncertainty.

physics.app-ph