Search arXivSearch

arXiv · 1907.09469

On-the-fly particle metrology in hollow-core photonic crystal fibre

Abstract

Efficient monitoring of airborne particulate matter (PM), especially particles with aerodynamic diameter less than 2.5 um (PM2.5), is crucial for improving public health. Reliable information on the concentration, size distribution and chemical characteristics of PMs is key to evaluating air pollution and identifying its sources. Standard methods for PM2.5 characterization require sample collection from the atmosphere and post-analysis using sophisticated equipment in a laboratory environment, and are normally very time-consuming. Although optical methods based on analysis of scattering of free-space laser beams or evanescent fields are in principle suitable for real-time particle counting and sizing, lack of knowledge of the refractive index in these methods not only leads to inevitable sizing ambiguity but also prevents identification of the particle material. In the case of evanescent wave detection, the system lifetime is strongly limited by adhesion of particles to the surfaces. Here we report a novel technique for airborne particle metrology based on hollow-core photonic crystal fibre. It offers in situ particle counting, sizing and refractive index measurement with effectively unlimited device lifetime, and relies on optical forces that automatically capture airborne particles in front of the hollow core and propel them into the fibre. The resulting transmission drop, together with the time-of-flight of the particles passing through the fibre, provide unambiguous mapping of particle size and refractive index with high accuracy. The technique represents a considerable advance over currently available real-time particle metrology systems, and can be directly applied to monitoring air pollution in the open atmosphere as well as precise particle characterization in a local environment such as a closed room or a reaction vessel.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Abhinav Sharma, Shangran Xie, Richard Zeltner, Philip St. J. Russell. 2019-07-21. On-the-fly particle metrology in hollow-core photonic crystal fibre. https://doi.org/10.1364/oe.27.034496

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

RCS angular control with gradient metasurfaces: design and measurement

This letter proposes the design and measurement of a periodic metasurface that achieves anomalous reflection with reduced RCS in a given parasitic direction. A previous study proposed a semi-analytical model to predict the RCS behavior of such a metasurface. However, this first study did not include any experimental exploration to verify the theoretical results. To complete this study, this work presents an experimental validation of the proposed design, with a focus on manufacturing and measurement issues. The synthesis, design specifications, fabrication method and experimental setup are presented and discussed. Measurement results are also examined in detail, highlighting some limitations in metasurfaces RCS measurements. The proposed metasurface effectively achieves the predicted RCS level reduction in the considered parasitic direction. The agreement between simulation and experimental results demonstrates the accuracy of the modelling and the efficiency of the optimisation procedure.

physics.app-ph

Maximum-Power-Transfer Power Coordinates for Fully Coupled Multiport Thévenin Sources

A power-normalized scattering representation is developed at a fixed frequency for a passive linear time-invariant multiport load driven by a fully coupled multiport Thévenin source. The source is obtained by reducing, at the load reference planes, an independent-source network whose suppressed internal impedance is passive, together with an intervening passive matching network. No diagonal-reference, uncoupled-source-channel, reciprocity, or commutation assumption is required. With $R_s=\mathrm{Herm}\{Z_s\}\succ\mathbf{0}$, completing the square in accepted power identifies the available-power current and motivates the coordinates $\mathbf{a}=\frac12R_s^{-1/2}(\mathbf{V}+Z_s\mathbf{I})$, $\mathbf{b}=\frac12R_s^{-1/2}(\mathbf{V}-Z_s^H\mathbf{I})$. They satisfy $\|\mathbf{a}\|_2^2-\|\mathbf{b}\|_2^2=\Re\{\mathbf{I}^H\mathbf{V}\}$ and yield $\mathbf{S}=R_s^{-1/2}(Z_{load}-Z_s^H)(Z_{load}+Z_s)^{-1}R_s^{1/2}$. An exact operator identity establishes passivity--contractivity equivalence and gives excitation-specific, reachable-subspace, and complete conjugate-matching conditions. On the physically reachable incident subspace, singular values characterize the best- and worst-case source-normalized port-reflection TARC, while a restricted Frobenius norm gives the basis-averaged squared TARC. Equal-magnitude phase-only control is formulated separately as a constant-modulus problem, with generator-side constraints mapped through the coupled source network before power normalization. For antenna loads and excitations with $P_{acc}>0$, $P_{rad}/P_{av}=η_{rad}(1-\mathrm{TARC}^2)$, so terminal scattering data alone do not determine radiation efficiency. When $R_s$ is singular, finite available power exists exactly for $\mathbf{E}\in\mathrm{range}(R_s)$, and the construction applies on the positive-resistance support.

physics.app-ph

Bimorph Lithium Niobate Thickness-Shear Overtone Film Bulk Acoustic Resonator

High quality factor ($Q$) and overtone operation enable narrow-linewidth acoustic devices with multiple discrete frequencies in a single cavity. Maintaining both high $Q$ and sufficient electromechanical coupling at higher mode orders remains challenging. Here, we demonstrate a bimorph periodically poled piezoelectric film (P3F) lithium niobate (LN) platform for high-order thickness-shear (TS) overtone excitation. The device comprises a bonded 80-$μ$m-thick single-crystal X-cut LN bimorph with opposite polarizations, patterned top and floating bottom electrodes, and a suspended air cavity. The P3F configuration mitigates charge cancellation from the alternating stress distribution of higher-order TS modes, enabling measurable coupling across a broad sequence of overtones. The thick LN acoustic cavity and increasingly confined high-order mode profiles support low-loss operation. Measured TS overtones extend to 1.75 GHz. At room temperature, representative overtones at 0.77 and 0.89 GHz exhibit 3-dB $Q$ values of 11,338 and 11,917, corresponding to $fQ$ products of $8.74\times10^{12}$ and $1.06\times10^{13}$ Hz, respectively. Cooling from 297 to 12 K systematically enhances $Q$, yielding a peak 3-dB $Q$ of 20,507 at 779 MHz and a maximum $fQ$ product of $1.98\times10^{13}$ Hz at 1.379 GHz. These results establish bimorph P3F LN as a promising platform for high-$Q$, frequency-scalable micro-acoustic resonators in the sub-GHz and low-GHz regimes.

physics.app-ph