Search arXiv⌕ Search

arXiv · 1908.00632

Liquid Marble Photosensor

Abstract

A liquid marble is a liquid droplet coated by a hydrophobic power. The liquid marble does not wet adjacent surfaces and therefore can be manipulated as a dry soft body. A Belousov-Zhabotinsky (BZ) reaction is an oscillatory chemical reaction exhibiting waves of oxidation. We demonstrate how to make a photo-sensor from BZ medium liquid marbles. We insert electrodes into a liquid marble, prepared from BZ solution and coated with polyethylene powder. The electrodes record a potential difference which oscillates due to oxidation wave-fronts crossing the electrodes. When the BZ marble is illuminated by a light source, the oxidation wave-fronts are hindered and, thus, the electrical potential recorded ceases to oscillate. We characterise several types of responses of BZ marble photosensors to various stimuli, and provide explanations of the recorded activity. BZ liquid marble photosensors may find applications in the fields of liquid electronics, soft robotics and unconventional computing.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrew Adamatzky, Michail-Antisthenis Tsompanas, Thomas C. Draper, Richard Mayne. 2019-08-01. Liquid Marble Photosensor. https://doi.org/10.1002/cphc.201900949

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Whole-Blood Boundary Analysis of BioFET-Based ctDNA Detection for Intravascular Sensing in Intrabody Nanonetworks

Liquid biopsy can detect tumor-derived biomarkers such as circulating tumor DNA (ctDNA), but ultra-low-fraction assays remain costly, slow, and difficult to scale. This motivates interest in intravascular in vivo sensing in the context of intrabody nanonetworks, where nanosensors could support local biomarker monitoring. BioFET-based nanosensors are relevant here because they are label-free, highly miniaturizable, and have shown strong ctDNA sensitivity in controlled media. We examine whether this sensitivity still yields reliable ctDNA detection in whole blood using a reduced-order stochastic simulation model that links operating-point selection, Debye-screened charge transduction, stochastic finite-capacity binding, nonspecific adsorption, background fluctuations, and intrinsic electronic noise to blank-threshold detection. Monte Carlo evaluation with physiologically grounded parameters shows that short Debye length and several-nanometer charge-to-channel separation attenuate the current shift, while low-frequency noise and background fluctuations reduce the margin between target-present and blank responses. Under the tested quasi-static charge-gating regime, the simulated current shifts do not reliably exceed the blank-derived threshold at low ctDNA concentrations. The model therefore provides a whole-blood boundary analysis that identifies which interface configurations and operating conditions most strongly limit reliable BioFET-based intravascular ctDNA detection.

cs.ET↗

Beyond HBM-on-GPU: Thermal Design Envelope for 3D Volumetric DRAM-on-GPU Integration

The scaling of GPUs for AI and HPC workloads is increasingly constrained by the capacity, bandwidth, and thermal limits of both 2.5D HBM-GPU and direct-stacked 3D HBM-on-GPU integration. This work establishes the thermal design envelope for 3D volumetric DRAM-on-GPU integration, in which vertically oriented DRAM dies and interleaved cooling cavities reshape heat flow and memory interfacing above the GPU. Using a package-level thermal model anchored to a consistent HBM-on-GPU baseline and driven by a realistic reticle-scale non-uniform GPU power map, we quantify the key parameters governing thermal feasibility. Stack height is the dominant limiter of peak temperature, while cooling-cavity conductivity shifts the feasible region, and mold insertion and stack orientation further modulate thermal behavior. A distributed memory-controller and network-on-chip tier introduces only a moderate thermal penalty. Although die-level parallelism increases bandwidth, the reduction in simulated training time saturates once execution becomes compute-bound. These results define a bounded co-design space across bandwidth, capacity, and thermal constraints for 3D volumetric DRAM-on-GPU integration.

cs.ET↗

Droop-Aware Foundation Model Power Flow

This paper develops a droop-aware extension of the GridFM power systems foundation model, embedding droop gains and frequency/voltage deadband parameters as per-bus node features to enable control-aware AC power-flow analysis. Existing power-flow datasets encode only static electrical features, conflating operating points from qualitatively different control regimes; this work resolves that gap by exposing droop and deadband parameters as structured node features, with deadband discontinuities handled through a smooth tanh approximation that preserves solver differentiability. A transformer-based graph neural network is pre-trained on masked reconstruction and fine-tuned on the resulting control-aware datasets. The framework is validated against PSCAD electromagnetic-transient simulations on a two-bus system (0.11% maximum steady-state error) and cross-validated against an independent PyPower droop solver on the IEEE 24-bus RTS. On the 24-bus system the surrogate attains R2 = 0.9996 for active generation and 0.0015 p.u. voltage-magnitude RMSE; scalability is confirmed on the IEEE 300-bus system (0.0036 p.u. RMSE, R2 = 0.9841 for voltage magnitude across 299,700 predictions). A three-mode control study further shows that the deadband widens the control-error distribution while leaving total droop compensation unchanged, establishing deadband width as an actionable node-level design feature.

cs.ET↗