Amplitude-tuneable, octal LED pulser for emulation of scintillation light in multi-channel photon detectors

Abstract

Photon detectors like the ALICE Calorimeters are vulnerable to both optical and electrical crosstalk between detector channels belonging to the same particle event. In order to quantify the crosstalk generated by a single channel on its neighbours, the standard method used so far are calibrated electrical pulses in order to quantify the crosstalk between individual frontend preamplifier channels. However due to grounding imperfections, cross-couplings via bias voltage supplies and imperfect electromagnetic shielding, this method introduces biases and is not precise. A new approach is the use of emulated scintillation light over optical fibre bundles in order to effectively generate scintillation light in clustered channels. This method is based on generation of quasi time-coherent light with similar time profiles as scintillation light. Theoretically, and based on linear superposition, pulsing a single channel with calibrated light would be sufficient to measure the crosstalk in the surrounding channels. However, non-linear effects in real detector frontends with energy measurements over cluster sizes like 3x3 can add up to significant errors. Non-linearity is for example due to preamplifier supply voltage drop in the distribution and GND return lines, in particular if power is provided over long cables. This can generate locally reduced or increased signal amplitudes depending on cumulative signal intensity. The presented octal light ALED~(Analogue LED) pulser prototype emulates scintillation light with individually tunable light amplitudes in 8 channels. It can be used for pulsing single channels, or for clustered channels with a predefined amplitude profile. Unbiased single channel crosstalk and non-linear side-effects can be determined for single and multichannel situations.

Explore related subjects

Keep this discovery

BibTeXRIS

Alexandru Rusu, Hans Muller. 2019-09-05. Amplitude-tuneable, octal LED pulser for emulation of scintillation light in multi-channel photon detectors. https://arxiv.org/abs/1909.02520

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det