Search arXivSearch

arXiv · 1909.02782

Towards a background-free neutrinoless double beta decay experiment based on a fluorescent bicolor sensor

Abstract

Searching for neutrinoless double beta decays ($\beta\beta0\nu$) is the only practical way to establish if the neutrinos are their own antiparticles. Due to the smallness of neutrino masses, the lifetime of $\beta\beta0\nu$ is expected to be at least ten orders of magnitude smaller than the noise associated with the natural radioactive chains. A positive identification of $\beta\beta0\nu$ decays requires, ultimately, finding a signal that cannot be mimicked by radioactive backgrounds. This signal could be the observation of the daughter atom in the decay, since no known background processes induce a Z+2 transformation. In particular, the $\beta\beta0\nu$ decay of Xe-136 could be established by detecting the doubly ionised daughter atom, Ba$^{2+}$. Such a detection could be achieved via a sensor made of a monolayer of molecular indicators. The Ba$^{2+}$ would be captured by one of the molecules in the sensor, and the presence of the single chelated indicator would be subsequently revealed by a strong fluorescent response from repeated interrogation with a laser system. Here we describe a fluorescent bicolor indicator that binds strongly to Ba$^{2+}$ and shines very brightly, shifting its emission colour from green to blue when chelated in dry medium, thus allowing the unambiguous identification of single barium atoms in the sensor, and permitting a positive identification of the $\beta\beta0\nu$ decay of Xe-136 in a gas chamber, that could led to a background-free experiment.

Explore related subjects

Keep this discovery

BibTeXRIS

Iván Rivilla, Borja Aparicio, Juan M. Bueno, David Casanova, Claire Tonnelé, Zoraida Freixa, Pablo Herrero, José I. Miranda, Rosa M. Martínez-Ojeda, Francesc Monrabal, Beñat Olave, Thomas Schäfer, Pablo Artal, David Nygren, Fernando P. Cossío, Juan J. Gómez-Cadenas. 2019-09-06. Towards a background-free neutrinoless double beta decay experiment based on a fluorescent bicolor sensor. https://arxiv.org/abs/1909.02782

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det