Search arXivSearch

arXiv · 1909.04922

Cardiac SPECT Radiomics Features Repeatability and Reproducibility: A Multi Scanner Phantom Study

Abstract

Background: The aim of this study was to assess the robustness of cardiac SPECT radiomics features against changes in imaging settings including acquisition and reconstruction settings. Methods: Four scanners were used to acquire SPECT scans of a cardiac phantom with 5mCi of 99mTc. The effects of different image acquisition and reconstruction settings including the Number of View, View Matrix Size, attenuation correction, image reconstruction algorithm, number of iterations, number of subsets, type of filter, full width at half maximum (FWHM) of Gaussian filter, Butterworth filter order, and Butterworth filter cut-off were studied. In total 5263 different images were reconstructed. Eighty-seven radiomic features including first, second, and high order textures were extracted from images. To assess reproducibility and repeatability the coefficient of variation (COV) was used for each image feature over the different imaging settings. Result: IDMN and IDN features from GLCM, RP from GLRLM, ZE from GLSZM, and DE from GLDM feature sets were the only features that were the most reproducible (COV < 5) against changes in all imaging settings. In addition, the IDMN feature from GLCM, LALGLE, SALGLE and LGLZE from GLSZM, and SDLGLE from GLDM feature sets were the features that were less reproducible (COV>20 ) against changes in all imaging settings. Matrix size has the greatest impact on feature variability as most of features are not repeatable and 82.76 of them had (COV>20 ). Conclusion: Repeatability and reproducibility of SPECT radiomics texture features in different imaging settings is feature-dependent, and different image acquisitions and reconstructions have different effects on radiomics texture features. Low COV radiomics features could be consider for further clinical studies. Keywords: SPECT, Radiomics, Cardiac, Repeatability, Reproducibility

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mohammad Edalat-Javid, Isaac Shiri, Ghasem Hajianfar, Hamid Abdollahi, Niki Oveisi, Mohammad Javadian, Mojtaba Shamsaei Zafarghandi, Hadi Malek, Ahmad Bitarafan-Rajabi, Mehrdad Oveisi. 2019-09-11. Cardiac SPECT Radiomics Features Repeatability and Reproducibility: A Multi Scanner Phantom Study. https://doi.org/10.1007/s12350-020-02109-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Prediction of biological radiation effects based on ionization clusters (nanodosimetry)

This article reviews approaches that link the formation of ionization clusters in nanometric volumes to radiobiological effectiveness. The corresponding models were developed as the field of nanodosimetry developed. Some address early biological radiation effects, such as DNA damage, while most aim to predict cell survival or inactivation. The models also differ in the nanodosimetric quantities considered, with many based on the probability distribution of ionization cluster formation in a single target. Some models account for the synergistic effects of pairs of ionization clusters formed in different targets. Several models feature macroscopic aggregation frameworks based on particle fluence, which are proposed for use in radiotherapy treatment planning, particularly in ion-beam radiotherapy. The models are presented here using harmonized terminology and notation for nanodosimetric quantities. An extension of the conceptual framework of nanodosimetry is also discussed. This extension transitions from a target-centered description to a track-centered description. It also introduces nanodosimetry-based analogs of dosimetric concepts, such as dose and linear energy transfer. This paper traces and summarizes the historical development of nanodosimetry-based biological effect models and discusses conceptual aspects of the models to reveal their underlying assumptions and the extent to which they are mechanistic or merely elucidate correlations. Eventually, an attempt is made to identify the key open questions in this field that still need to be addressed.

physics.med-ph

Contextual Cellular Growth (ConCeG) of neural cells for realistic grey matter tissue generation for diffusion MRI simulations

Accurate interpretation of diffusion magnetic resonance imaging (dMRI) signals in grey matter (GM) remains challenging due to the complex, heterogeneous, and densely packed cellular environment. Numerical phantoms provide a controlled framework for investigating the relationship between microstructure and diffusion signals, yet existing approaches often lack the morphological realism and multi-cellular organisation required to faithfully represent GM tissue. In this work, we introduce Contextual Cellular Growth (ConCeG), a generative framework for creating individual cells or constructing dense, three-dimensional, multi-cellular GM substrates informed by real neuronal and glial morphologies. The method combines topological neuron synthesis with a spatially constrained growth network, allowing for the controlled generation of heterogeneous cellular environments with realistic intra- and extracellular compartments. Synthetic cells are generated using morphological and topological characteristics derived from biological reconstructions. We validate the framework through comparisons of structural features with real cellular data, demonstrating strong agreement in branch order, length, angle, and tortuosity distributions. Power spectrum analysis further shows that both intracellular compartments reproduce the spatial correlations observed in biological tissue. Together, these results show ConCeG provides a biologically grounded framework for generating grey matter substrates suitable for large scale diffusion MRI simulation.

physics.med-ph

Magnetic Field of Firing Neuron in Humans: Measurable by Quantum Sensing MRI?

Firing neurons generate action potentials that propagate along axons to transmit signals supporting cognitive functions. These electrical currents generate magnetic fields, yet direct detection of these neuronal magnetic fields by MRI remains elusive. This Mini Review investigates why this goal has been proven difficult to achieve and whether an emerging approach, quantum sensing MRI, can overcome the challenge.

physics.med-ph